inlclusion loop and adding dead nodes when using SmartStart but using not supported S2 Security Classed #1078

Open
PackElend opened this issue Jan 18, 2025 · 0 comments

Comments

@PackElend
Copy link

Describe the bug
When I try to include the device, but only enable S2 security classes that are not supported by the device, it tries to include as soon as it receives the inclusion request. It creates a node in the object tree but aborts the inclusion. A few seconds later, the cycle starts again, filling the object tree with dead, incomplete nodes.
As soon as I enable a supported security class, the device is successfully added and the loop stops.

My Gateway: Z-Wave.me RaZberry 7 Pro
My Device: Wave Shutter (EU)

To Reproduce
Steps to reproduce the behaviour:

  1. add adapter, only select the serial port
  2. Generate Security Keys in the Adapter Settings
  3. Add QR Code in SmartStart
  4. Activate only S2 AC (not supported by most devices)
  5. Power up device

Expected behaviour
not doing anything, may saying there is S2 capable device and advising to allow other Security Classes.

Screenshots & Logfiles

Versions:

  • Adapter version: v3.1.0
  • JS-Controller version: 7.0.6
  • Node version: v20.18.1
  • Operating system: docker image on Raspberry Pi OS

Additional context
Add any other context about the problem here. If you have specific problems with devices, please include the information that is requested under troubleshooting.