Looking into the UART initialization code for SBUS input I found different settings:

Horus: 2 stop bits
Taranis 1 stop bit

AFAIK the 2 stop bits are correct.

(see also: #1462 )

@gagarinlg
Copy link
Member

is this still an issue?

@richardclli
Copy link
Collaborator

is this still an issue?

I do not think it is still there after @raphaelcoeffic changed the serial module API, all code should be shared now,. @wimalopaan Any comments?

@wimalopaan
Copy link
Contributor Author

I think it is fixed by the rewrite. But I did not make any checks ...