Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathhoymiles_setlimiter.py
223 lines (192 loc) · 7.43 KB
/
hoymiles_setlimiter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
# !/usr/bin/python
# -*- coding: utf-8 -*-
# Dank geht an https://github.com/tbnobody/OpenDTU
# Version 0.95 PFu 28.10.2022
# das Script ermittelt den aktuellen Bezug eines Stromzählers. Dazu wird der schon
# laufende Volkszähler abgefragt. Sonst den json vom Smartmeter nehmen etc.
# SunMan ist mein flexibles Modul mit 375Wp von SunMan
# die Seriennummer anpassen und die gewünschte zuweisen
# die apiURL mit dem Zugang zum Volkszähler muss angepasst werden
# maximum_wr muss angepasst werden auf max Wechselrichter oder Modulleistung
import paho.mqtt.client as mqtt
from influxdb import InfluxDBClient
import requests
import json
import time
import sys
# Seriennummern der Hoymiles Wechselrichter
serial_SunMan = "112174217122"
serial_Trina = "112174217264"
maximum_wr = 400
# was kann das Modul / WR max abgeben
# hier die passende Seriennummer zuweisen
serial = serial_Trina
# mqtt-strings zum lesen und schreiben zusammensetzen
set_limit = "solar/"+serial+"/cmd/limit_nonpersistent_absolute"
akt_power = "solar/"+serial+"/0/power" # aktuelle Lieferung ins Haus
akt_p_dc = "solar/"+serial+"/0/powerdc" # aktuelle Lieferung vom Panel
limit_alt = "solar/"+serial+"/status/limit_absolute" # das vorherige Limit
akt_reachable = "solar/"+serial+"/status/reachable"
akt_producing = "solar/"+serial+"/status/producing"
MQTT_TOPIC = [(akt_power,0),(akt_p_dc,0),(limit_alt,0)]
# Zugang zum Volkszähler MiniWeb
apiURL = "http://192.168.200.207:8080" # miniweb des Volkszähler im Chalet
reachable = 1 # ist DTU erreichbar ?
producing = 1 # produziert der Wechselrichter etwas ?
grid_sum = 0 # aktueller Bezug im Chalet
setpoint = 0 # neues Limit in Watt
value = -1 # Rückgabewert
altes_limit = 0 # wo war das alte Limit gesetzt
power = 0 # Abgabe BKW AC in Watt
power_dc = 0 # Lieferung DC vom Panel
got_power = False
got_power_dc = False
# paho_mqtt läuft lokal
server = "localhost"
port = 1883
# Configure InfluxDB connection variables
influx_host = "localhost"
# influx_host = "192.168.22.210"
influx_port = 8086
user = "hoy"
password = "miles"
dbname = "dtu"
# Influx Datenbank verbinden
influx_client = InfluxDBClient(influx_host, influx_port, user, password, dbname)
# json zusammenbauen für Influx-Datenbank
def add(name,wert):
info=[{"measurement": "opendtu",
"fields": {name : wert}}]
print(info)
influx_client.write_points(info, time_precision='m')
return
# es wurde eine allgemeine mqtt Nachricht empfangen
def on_message(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
print("on_message",message_received)
# es wurde eine bestimmte mqtt Nachricht empfangen
def on_message_reachable(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
global reachable
reachable = int(float(message_received))
if reachable: print("DTU ist erreichbar!")
else:
print("Problem: DTU ist NICHT erreichbar!")
client.disconnect()
def on_message_producing(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
global producing
producing = int(float(message_received))
if producing: print("Wechselrichter arbeitet!")
else:
client.disconnect()
def on_message_power(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
global power
power = int(float(message_received))
if reachable: print("BKW liefert aktuell : ", power)
global got_power
got_power = True
if (got_power & got_power_dc):
client.disconnect()
def on_message_power_dc(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
global power_dc
power_dc = int(float(message_received))
if reachable: print("Panel liefert aktuell : ", power_dc)
global got_power_dc
got_power_dc = True
if (got_power & got_power_dc):
client.disconnect()
def on_message_altes_limit(client, userdata, message):
message_received = str(message.payload.decode("utf-8"))
global altes_limit
altes_limit = int(float(message_received))
if reachable:
print("altes_limit war bei : ", altes_limit)
if altes_limit >= maximum_wr:
altes_limit = maximum_wr
print(" altes Limit korrigiert auf ", maximum_wr)
# zum mqtt Broker verbunden
def on_connect(client, userdata, flags, rc):
#print(got_power,got_power_dc)
if rc==0:
client.connected_flag=True #set flag
print("MQTT erreichbar, connect ok")
time.sleep(1)
else:
print("MQTT, Bad connection Returned code=",rc)
def on_disconnect(client, userdata, rc):
print("MQTT: disconnected!")
# Bezug vom Chalet feststellen
r = requests.get(apiURL) # Volkszähler lesen
json_string = r.text
parsed_json = json.loads(json_string)
# hier anpassen an json Ausgabe
grid_sum = int(parsed_json['data'][1]['tuples'][0][1])
print(grid_sum)
# Strombezug ist jetzt bekannt
# ------------------------------------- Ende Chalet Bezug feststellen
# zum mqtt server verbinden
mqtt.Client.connected_flag=False #create flag in class
client = mqtt.Client("DTU")
client.connect(server,port)
#print("Skript: Statusabfragen laufen")
# auf bestimmte Messages reagieren
client.message_callback_add(akt_reachable, on_message_reachable)
client.message_callback_add(akt_power, on_message_power)
client.message_callback_add(akt_producing, on_message_producing)
client.message_callback_add(akt_p_dc, on_message_power_dc)
client.message_callback_add(limit_alt, on_message_altes_limit)
client.on_message = on_message
client.subscribe('solar/'+serial+'/#')
client.on_connect = on_connect
client.loop_forever()
#--------------------- Ende erster Teil: Datenermittlung
# Werte setzen
client = mqtt.Client("DTU-2")
client.connect(server,port)
# print("Skript: Limit setzen läuft")
client.loop_start()
client.subscribe(set_limit)
print("aktueller Bezug Chalet: ",grid_sum)
# print("Skript: Limiter korrigieren läuft")
# limiter korrigieren falls er maximum_wr übersteigt,
# falls mehr Strom bezogen wird als der Wechselrichter liefern könnte,
# oder falls nichts vom Wechselrichter kommt.
# oder wenn das Limit unter 100 Watt wäre (Versuchsweise)
if reachable:
if (altes_limit >= maximum_wr or grid_sum >= maximum_wr or setpoint >= maximum_wr):
print("setze Limiter auf maximum_wr")
setpoint = maximum_wr
# wir weniger bezogen als maximum_wr dann neues Limit ausrechnen
if (grid_sum+altes_limit) <= maximum_wr:
setpoint = grid_sum + altes_limit -5
print("setpoint:",grid_sum,"+",altes_limit,"-5 ")
print("neues Limit berechnet auf ",setpoint)
if setpoint <= 100:
setpoint = 100
print("setpoint: 100 minimum gesetzt")
print("neues Limit festgelegt auf ",setpoint)
print("setze Einspeiselimit auf: ",setpoint)
# neues limit setzen
client.publish(set_limit,setpoint)
print("Panel-power:",power," Setpoint:",setpoint)
time.sleep(2) # wait
# neues Limit mit 0 macht keinen Sinn, irgend ein Fehler..
if setpoint == 0: setpoint = grid_sum
if not reachable: setpoint = maximum_wr
client.loop_stop() #stop loop
client.disconnect() # disconnect
# Ausgabe an die Influx-Datenbank
if reachable == True:
add('altes_limit',altes_limit)
else:
add('altes_limit',setpoint)
add('reachable',int(reachable))
add('producing',int(producing))
add('akt_p_dc',int(power_dc))
add('akt_power',int(power))
add('grid_sum',int(grid_sum))
add('setpoint',int(setpoint))
# Ende Skript