You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
I'm super pumped to see that this has been ported over with IP usage. As a mechanical engineer without much debugging experience, I'm running this code and getting the following issue. Am I doing something wrong?
Thanks for the work getting this to work with IP units.
~\AppData\Roaming\Python\Python37\site-packages\psychrolib.py in GetSatVapPres(TDryBulb)
1022 if isIP():
1023 if (TDryBulb < -148 or TDryBulb > 392):
-> 1024 raise ValueError("Dry bulb temperature must be in range [-148, 392]°F")
1025
1026 T = GetTRankineFromTFahrenheit(TDryBulb)
ValueError: Dry bulb temperature must be in range [-148, 392]°F
The text was updated successfully, but these errors were encountered:
IP usage is too new, sorry :) I need to take some time to polish the plot logic so those errors get better treatment.
Anyway, I think your current problem is because you changed the unit system but the chart is working with plot limits adequate only for SI. Try to change this line:
I'm super pumped to see that this has been ported over with IP usage. As a mechanical engineer without much debugging experience, I'm running this code and getting the following issue. Am I doing something wrong?
Thanks for the work getting this to work with IP units.
ValueError Traceback (most recent call last)
in
5 from psychrochart import PsychroChart, load_config
6
----> 7 chart_ashrae_style = PsychroChart(use_unit_system_si=False)
8 ax = chart_ashrae_style.plot()
9 ax.get_figure()
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\chart.py in init(self, styles, zones_file, use_unit_system_si)
86 self._handlers_annotations: List = []
87
---> 88 self._make_chart_data(styles, zones_file)
89
90 def repr(self) -> str:
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\chart.py in _make_chart_data(self, styles, zones_file)
213 label_loc=self.chart_params.get("constant_v_labels_loc", 1.0),
214 family_label=self.chart_params["constant_v_label"],
--> 215 saturation_curve=self.saturation.curves[0],
216 )
217
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\chartdata.py in make_constant_specific_volume_lines(w_humidity_ratio_min, pressure, vol_values, v_label_values, style, label_loc, family_label, saturation_curve)
310 vol_values,
311 lambda *x: t_sat_interpolator(x[0]),
--> 312 lambda x: GetMoistAirVolume(
313 x, GetHumRatioFromVapPres(GetSatVapPres(x), pressure), pressure,
314 ),
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\util.py in solve_curves_with_iteration(family_name, objective_values, func_init, func_eval)
178 func_eval=func_eval,
179 initial_increment=initial_increment,
--> 180 precision=precision,
181 )
182 except AssertionError as exc: # pragma: no cover
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\util.py in _iter_solver(initial_value, objective_value, func_eval, initial_increment, num_iters_max, precision)
121 num_iter = 0
122 value_calc = initial_value.copy()
--> 123 error = objective_value - func_eval(initial_value)
124 while abs(error) > precision and num_iter < num_iters_max:
125 iteration_value = func_eval(value_calc)
~\AppData\Roaming\Python\Python37\site-packages\psychrochart\chartdata.py in (x)
311 lambda *x: t_sat_interpolator(x[0]),
312 lambda x: GetMoistAirVolume(
--> 313 x, GetHumRatioFromVapPres(GetSatVapPres(x), pressure), pressure,
314 ),
315 )
~\AppData\Roaming\Python\Python37\site-packages\psychrolib.py in GetSatVapPres(TDryBulb)
1022 if isIP():
1023 if (TDryBulb < -148 or TDryBulb > 392):
-> 1024 raise ValueError("Dry bulb temperature must be in range [-148, 392]°F")
1025
1026 T = GetTRankineFromTFahrenheit(TDryBulb)
ValueError: Dry bulb temperature must be in range [-148, 392]°F
The text was updated successfully, but these errors were encountered: