Hallo,
irgendwie geht da was nicht mit der 20.11.2024.

ESP32-S3 8MB, Oled,Pylontec,Victron,SML,(W5500)

Ich habe alles so eingestellt wie in der Version vorher, aber es wird kein Strom produziert.
Was ist hier falsch?

Dump von der Konsole:
[VE.Direct MPPT 12/11] serial input (242 Bytes):
19:36:24.441 > [VE.Direct MPPT 12/11] 3a 37 46 36 45 44 30 30 31 38 31 35 33 45 0a 3a
19:36:24.504 > [VE.Direct MPPT 12/11] 37 32 37 32 30 30 30 46 46 46 46 46 46 46 46 30
19:36:24.565 > [VE.Direct MPPT 12/11] 42 0a 3a 41 44 35 45 44 30 30 44 34 31 34 41 31
19:36:24.631 > [VE.Direct MPPT 12/11] 0a 3a 41 42 42 45 44 30 30 31 32 30 30 39 31 0a
19:36:24.682 > [VE.Direct MPPT 12/11] 0d 0a 50 49 44 09 30 78 41 30 37 33 0d 0a 46 57
19:36:24.738 > [VE.Direct MPPT 12/11] 09 31 36 34 0d 0a 53 45 52 23 09 48 51 32 32 34
19:36:24.804 > [VE.Direct MPPT 12/11] 38 48 39 41 34 33 0d 0a 56 09 35 33 33 32 30 0d
19:36:24.868 > [VE.Direct MPPT 12/11] 0a 49 09 30 0d 0a 56 50 56 09 31 39 30 0d 0a 50
19:36:24.919 > [VE.Direct MPPT 12/11] 50 56 09 30 0d 0a 43 53 09 30 0d 0a 4d 50 50 54
19:36:24.978 > [VE.Direct MPPT 12/11] 09 30 0d 0a 4f 52 09 30 78 30 30 30 30 30 30 30
19:36:25.033 > [VE.Direct MPPT 12/11] 31 0d 0a 45 52 52 09 30 0d 0a 4c 4f 41 44 09 4f
19:36:25.197 > [VE.Direct MPPT 12/11] 4e 0d 0a 48 31 39 09 35 34 38 35 0d 0a 48 32 30
19:36:25.255 > [VE.Direct MPPT 12/11] 09 39 30 0d 0a 48 32 31 09 33 30 38 0d 0a 48 32
19:36:25.327 > [VE.Direct MPPT 12/11] 32 09 37 39 0d 0a 48 32 33 09 32 36 35 0d 0a 48
19:36:25.387 > [VE.Direct MPPT 12/11] 53 44 53 09 34 37 0d 0a 43 68 65 63 6b 73 75 6d
19:36:25.437 > [VE.Direct MPPT 12/11] 09 f3
19:36:25.491 > [VE.Direct MPPT 12/11] Text Data 'PID' = '0XA073'
19:36:25.610 > [VE.Direct MPPT 12/11] Text Data 'FW' = '164'
19:36:25.656 > [VE.Direct MPPT 12/11] Text Data 'SER' = 'HQ2248------'
19:36:25.704 > [VE.Direct MPPT 12/11] Text Data 'V' = '53320'
19:36:25.749 > [VE.Direct MPPT 12/11] Text Data 'I' = '0'
19:36:25.797 > [VE.Direct MPPT 12/11] Text Data 'VPV' = '190'
19:36:25.853 > [VE.Direct MPPT 12/11] Text Data 'PPV' = '0'
19:36:25.909 > [VE.Direct MPPT 12/11] Text Data 'CS' = '0'
19:36:26.028 > [VE.Direct MPPT 12/11] Text Data 'MPPT' = '0'
19:36:26.089 > [VE.Direct MPPT 12/11] Text Data 'OR' = '0X00000001'
19:36:26.141 > [VE.Direct MPPT 12/11] Text Data 'ERR' = '0'
19:36:26.200 > [VE.Direct MPPT 12/11] Text Data 'LOAD' = 'ON'
19:36:26.283 > [VE.Direct MPPT 12/11] Text Data 'H19' = '5485'
19:36:26.346 > [VE.Direct MPPT 12/11] Text Data 'H20' = '90'
19:36:26.404 > [VE.Direct MPPT 12/11] Text Data 'H21' = '308'
19:36:26.463 > [VE.Direct MPPT 12/11] Text Data 'H22' = '79'
19:36:26.528 > [VE.Direct MPPT 12/11] Text Data 'H23' = '265'
19:36:26.604 > [VE.Direct MPPT 12/11] Text Data 'HSDS' = '47'
19:36:26.683 > [DPL::loop] ******************* ENTER **********************
19:36:26.762 > [DPL::loop] battery interface enabled, SoC: 99.0 %, StartTH: 90 %, StopTH: 20 %, SoC age: 1 s, ignore: no
19:36:26.852 > [DPL::getBatteryVoltage] BMS: 53.25 V, MPPT: 53.32 V, inverter 1164a------------: 53.40 V, returning: 53.25V
19:36:26.913 > [DPL::loop] dcVoltage: 53.25 V, loadCorrectedVoltage: 53.25 V, StartTH: 53.00 V, StopTH: 49.00 V
19:36:26.982 > [DPL::loop] StartTH reached: yes, StopTH reached: no, SolarPT disabled, use at night: yes
19:36:27.041 > [DPL::calcHouseholdConsumption] target consumption: 0 W, base load: 10 W
19:36:27.112 > [DPL::calcHouseholdConsumption] power meter value: 405.0 W, power meter valid: yes
19:36:27.174 > [DPL::calcHouseholdConsumption] inverter 1164a------------- is behind power meter producing 1 W
19:36:27.237 > [DPL::updateInverterLimits] requested: 406 W, producing: 0 W using 0 solar-powered inverters, diff: 406 W, hysteresis: 30 W
19:36:27.297 > [DPL::calcBatteryAllowance] power requested: 406 W
19:36:27.461 > [DPL::updateInverterLimits] requested: 406 W, producing: 1 W using 1 battery-powered inverters, diff: 405 W, hysteresis: 30 W
19:36:27.520 > [DPL::updateInverterLimits] will cover 1 W using battery-powered inverters
19:36:27.587 > [DPL inverter 1164a---------]:
19:36:27.641 >     battery-powered, producing 1 W
19:36:27.707 >     lower/current/upper limit: 10/0/500 W, output capability: 1600 W
19:36:27.771 >     sending commands enabled, reachable, disqualified
19:36:27.843 >     max reduction production/standby: 0/0 W, max increase: 0 W
19:36:27.899 >     target limit/output/state: -1 W (unchanged)/1 W/unchanged, 0 update timeouts
19:36:27.957 > [DPL::loop] consumption: 406 W, target output: 406 W (limited to 1500 W), solar inverters output: 0 W, battery allowance: 406 W, battery inverters output: 1 W
19:36:28.009 > [DPL::announceStatus] the system is stable, the last power limit is still valid
19:36:28.066 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDD5 (Charger Voltage), value: 0x000014D5, flags: 0x00
19:36:28.123 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDBB (Panel Voltage), value: 0x00000012, flags: 0x00
19:36:28.275 > Fetch inverter: 1164A-----------
19:36:28.323 > TX RealTimeRunData 865.00 MHz --> 15 A0 09 93 20 80 19 36 00 80 0B 00 67 46 15 29 00 00 00 00 00 00 00 00 DC 7D 97 
19:36:28.381 > [PowerMeterSerialSml] decoded energy import to -0.10
19:36:28.443 > [PowerMeterSerialSml] decoded energy import to 1514999.75
19:36:28.509 > [PowerMeterSerialSml] decoded energy export to -10.00
19:36:28.626 > [PowerMeterSerialSml] decoded energy export to 462664.91
19:36:28.734 > [PowerMeterSerialSml] decoded active power total to 396.00
19:36:28.851 > [PowerMeterSerialSml] decoded active power total to 396.00
19:36:28.952 > [PowerMeterSerialSml] checksum verification failed
19:36:29.037 > Interrupt received
19:36:29.141 > RX 865.00 MHz --> 95 A0 09 93 20 80 19 36 00 01 00 01 02 16 02 16 00 01 00 00 00 07 00 04 00 00 22 | -7 dBm
19:36:29.245 > Websocket: [/livedata][16] disconnect
19:36:29.354 > Websocket: [/vedirectlivedata][14] disconnect
19:36:29.551 > Websocket: [/batterylivedata][14] disconnect
19:36:29.611 > Interrupt received
19:36:29.664 > RX 865.00 MHz --> 95 A0 09 93 20 80 19 36 00 02 32 A8 00 00 32 29 00 18 00 12 02 16 02 17 00 00 A8 | -7 dBm
19:36:29.802 > [VE.Direct MPPT 12/11] serial input (208 Bytes):
19:36:29.856 > [VE.Direct MPPT 12/11] 3a 41 44 35 45 44 30 30 44 35 31 34 41 30 0a 3a
19:36:29.918 > [VE.Direct MPPT 12/11] 41 42 42 45 44 30 30 31 32 30 30 39 31 0a 0d 0a
19:36:29.988 > [VE.Direct MPPT 12/11] 50 49 44 09 30 78 41 30 37 33 0d 0a 46 57 09 31
19:36:30.048 > [VE.Direct MPPT 12/11] 36 34 0d 0a 53 45 52 23 09 48 51 32 32 34 38 48
19:36:30.100 > [VE.Direct MPPT 12/11] 39 41 34 33 0d 0a 56 09 35 33 33 33 30 0d 0a 49
19:36:30.155 > [VE.Direct MPPT 12/11] 09 30 0d 0a 56 50 56 09 31 39 30 0d 0a 50 50 56
19:36:30.207 > [VE.Direct MPPT 12/11] 09 30 0d 0a 43 53 09 30 0d 0a 4d 50 50 54 09 30
19:36:30.266 > [VE.Direct MPPT 12/11] 0d 0a 4f 52 09 30 78 30 30 30 30 30 30 30 31 0d
19:36:30.319 > [VE.Direct MPPT 12/11] 0a 45 52 52 09 30 0d 0a 4c 4f 41 44 09 4f 4e 0d
19:36:30.364 > [VE.Direct MPPT 12/11] 0a 48 31 39 09 35 34 38 35 0d 0a 48 32 30 09 39
19:36:30.423 > [VE.Direct MPPT 12/11] 30 0d 0a 48 32 31 09 33 30 38 0d 0a 48 32 32 09
19:36:30.475 > [VE.Direct MPPT 12/11] 37 39 0d 0a 48 32 33 09 32 36 35 0d 0a 48 53 44
19:36:30.531 > [VE.Direct MPPT 12/11] 53 09 34 37 0d 0a 43 68 65 63 6b 73 75 6d 09 f2
19:36:30.595 > [VE.Direct MPPT 12/11] Text Data 'PID' = '0XA073'
19:36:30.655 > [VE.Direct MPPT 12/11] Text Data 'FW' = '164'
19:36:30.714 > [VE.Direct MPPT 12/11] Text Data 'SER' = 'HQ22-------'
19:36:30.771 > [VE.Direct MPPT 12/11] Text Data 'V' = '53330'
19:36:30.821 > [VE.Direct MPPT 12/11] Text Data 'I' = '0'
19:36:30.874 > [VE.Direct MPPT 12/11] Text Data 'VPV' = '190'
19:36:30.931 > [VE.Direct MPPT 12/11] Text Data 'PPV' = '0'
19:36:30.987 > [VE.Direct MPPT 12/11] Text Data 'CS' = '0'
19:36:31.040 > [VE.Direct MPPT 12/11] Text Data 'MPPT' = '0'
19:36:31.096 > [VE.Direct MPPT 12/11] Text Data 'OR' = '0X00000001'
19:36:31.150 > [VE.Direct MPPT 12/11] Text Data 'ERR' = '0'
19:36:31.197 > [VE.Direct MPPT 12/11] Text Data 'LOAD' = 'ON'
19:36:31.256 > [VE.Direct MPPT 12/11] Text Data 'H19' = '5485'
19:36:31.306 > [VE.Direct MPPT 12/11] Text Data 'H20' = '90'
19:36:31.354 > [VE.Direct MPPT 12/11] Text Data 'H21' = '308'
19:36:31.412 > [VE.Direct MPPT 12/11] Text Data 'H22' = '79'
19:36:31.476 > [VE.Direct MPPT 12/11] Text Data 'H23' = '265'
19:36:31.529 > [VE.Direct MPPT 12/11] Text Data 'HSDS' = '47'
19:36:31.574 > Interrupt received
19:36:31.632 > RX 865.00 MHz --> 95 A0 09 93 20 80 19 36 00 03 00 00 00 03 00 02 00 00 2A ED 00 00 28 AD 00 0B 6B | -7 dBm
19:36:31.691 > [VE.Direct MPPT 12/11] Sending Hex Command: :7ECED0075, Free FIFO-Buffer: 118
19:36:31.758 > [VE.Direct MPPT 12/11] Hex Data: Smart Battery Sense Temperature is not available
19:36:31.810 > [VE.Direct MPPT 12/11] Sending Hex Command: :727200007, Free FIFO-Buffer: 118
19:36:31.869 > [VE.Direct MPPT 12/11] Hex Data: Network total DC power value indicates non-networked controller
19:36:31.929 > RX Period End
19:36:31.981 > Last missing
19:36:32.041 > Request retransmit: 4
19:36:32.102 > TX RequestFrame 865.00 MHz --> 15 A0 09 93 20 80 19 36 00 84 24 
19:36:32.156 > Interrupt received
19:36:32.212 > RX 865.00 MHz --> 95 A0 09 93 20 80 19 36 00 04 00 0B 09 44 13 89 00 03 00 00 00 00 03 E8 00 B3 A3 | -7 dBm
19:36:32.264 > RX Period End
19:36:32.311 > Last missing
19:36:32.359 > Request retransmit: 5
19:36:32.419 > TX RequestFrame 865.00 MHz --> 15 A0 09 93 20 80 19 36 00 85 25 
19:36:32.482 > [VE.Direct MPPT 12/11] Sending Hex Command: :7DBED0086, Free FIFO-Buffer: 118
19:36:32.569 > Interrupt received
19:36:32.661 > RX 865.00 MHz --> 95 A0 09 93 20 80 19 36 00 85 00 01 B0 D3 C7 | -7 dBm
19:36:32.734 > [VE.Direct MPPT 12/11] Hex Data: MPPT Temperature (0xEDDB): 23.70°C
19:36:32.784 > [VE.Direct MPPT 12/11] Sending Hex Command: :7F7ED006A, Free FIFO-Buffer: 118
19:36:32.843 > [VE.Direct MPPT 12/11] Hex Data: MPPT Absorption Voltage (0xEDF7): 56.80V
19:36:32.894 > RX Period End
19:36:32.941 > Success
19:36:32.988 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDD5 (Charger Voltage), value: 0x000014D4, flags: 0x00
19:36:33.043 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDBB (Panel Voltage), value: 0x00000012, flags: 0x00
19:36:33.106 > [DPL::loop] ******************* ENTER **********************
19:36:33.178 > [DPL::loop] battery interface enabled, SoC: 99.0 %, StartTH: 90 %, StopTH: 20 %, SoC age: 2 s, ignore: no
19:36:33.235 > [DPL::getBatteryVoltage] BMS: 53.25 V, MPPT: 53.33 V, inverter 1164a------------: 53.40 V, returning: 53.25V
19:36:33.298 > [DPL::loop] dcVoltage: 53.25 V, loadCorrectedVoltage: 53.25 V, StartTH: 53.00 V, StopTH: 49.00 V
19:36:33.361 > [DPL::loop] StartTH reached: yes, StopTH reached: no, SolarPT disabled, use at night: yes
19:36:33.422 > [DPL::calcHouseholdConsumption] target consumption: 0 W, base load: 10 W
19:36:33.486 > [DPL::calcHouseholdConsumption] power meter value: 405.0 W, power meter valid: yes
19:36:33.549 > [DPL::calcHouseholdConsumption] inverter 1164a---------- is behind power meter producing 0 W
19:36:33.634 > [PowerMeterSerialSml] decoded energy import to -0.10
19:36:33.731 > [DPL::updateInverterLimits] requested: 405 W, producing: 0 W using 0 solar-powered inverters, diff: 405 W, hysteresis: 30 W
19:36:33.811 > [PowerMeterSerialSml] decoded energy import to 1514999.75
19:36:33.929 > [DPL::calcBatteryAllowance] power requested: 405 W
19:36:34.034 > [DPL::updateInverterLimits] requested: 405 W, producing: 0 W using 1 battery-powered inverters, diff: 405 W, hysteresis: 30 W
19:36:34.094 > [PowerMeterSerialSml] decoded energy export to -10.00
19:36:34.153 > [DPL::updateInverterLimits] will cover 0 W using battery-powered inverters
19:36:34.206 > [PowerMeterSerialSml] decoded energy export to 462664.91
19:36:34.272 > [PowerMeterSerialSml] decoded active power total to 385.00
19:36:34.333 > [DPL inverter 1164a00-----------]:
19:36:34.392 >     battery-powered, producing 0 W
19:36:34.494 >     lower/current/upper limit: 10/0/500 W, output capability: 1600 W
19:36:34.546 >     sending commands enabled, reachable, disqualified
19:36:34.591 >     max reduction production/standby: 0/0 W, max increase: 0 W
19:36:34.648 >     target limit/output/state: -1 W (unchanged)/0 W/unchanged, 0 update timeouts
19:36:34.714 > [PowerMeterSerialSml] decoded active power total to 385.00
19:36:34.770 > [DPL::loop] consumption: 405 W, target output: 405 W (limited to 1500 W), solar inverters output: 0 W, battery allowance: 405 W, battery inverters output: 0 W
19:36:34.828 > [PowerMeterSerialSml] TotalPower: 385.00
19:36:34.873 > [VE.Direct MPPT 12/11] serial input (272 Bytes):
19:36:34.935 > [VE.Direct MPPT 12/11] 3a 37 45 43 45 44 30 30 46 46 46 46 37 37 0a 3a
19:36:34.983 > [VE.Direct MPPT 12/11] 37 32 37 32 30 30 30 46 46 46 46 46 46 46 46 30
19:36:35.042 > [VE.Direct MPPT 12/11] 42 0a 3a 37 44 42 45 44 30 30 34 32 30 39 33 42
19:36:35.107 > [VE.Direct MPPT 12/11] 0a 3a 37 46 37 45 44 30 30 33 30 31 36 32 34 0a
19:36:35.162 > [VE.Direct MPPT 12/11] 3a 41 44 35 45 44 30 30 44 34 31 34 41 31 0a 3a
19:36:35.327 > [VE.Direct MPPT 12/11] 41 42 42 45 44 30 30 31 32 30 30 39 31 0a 0d 0a
19:36:35.385 > [VE.Direct MPPT 12/11] 50 49 44 09 30 78 41 30 37 33 0d 0a 46 57 09 31
19:36:35.539 > [VE.Direct MPPT 12/11] 36 34 0d 0a 53 45 52 23 09 48 51 32 32 34 38 48
19:36:35.634 > [VE.Direct MPPT 12/11] 39 41 34 33 0d 0a 56 09 35 33 33 32 30 0d 0a 49
19:36:35.737 > [VE.Direct MPPT 12/11] 09 30 0d 0a 56 50 56 09 31 38 30 0d 0a 50 50 56
19:36:35.796 > [VE.Direct MPPT 12/11] 09 30 0d 0a 43 53 09 30 0d 0a 4d 50 50 54 09 30
19:36:35.859 > [VE.Direct MPPT 12/11] 0d 0a 4f 52 09 30 78 30 30 30 30 30 30 30 31 0d
19:36:35.911 > [VE.Direct MPPT 12/11] 0a 45 52 52 09 30 0d 0a 4c 4f 41 44 09 4f 4e 0d
19:36:35.957 > [VE.Direct MPPT 12/11] 0a 48 31 39 09 35 34 38 35 0d 0a 48 32 30 09 39
19:36:36.005 > [VE.Direct MPPT 12/11] 30 0d 0a 48 32 31 09 33 30 38 0d 0a 48 32 32 09
19:36:36.059 > [VE.Direct MPPT 12/11] 37 39 0d 0a 48 32 33 09 32 36 35 0d 0a 48 53 44
19:36:36.146 > [VE.Direct MPPT 12/11] 53 09 34 37 0d 0a 43 68 65 63 6b 73 75 6d 09 f4
19:36:36.194 > [VE.Direct MPPT 12/11] Text Data 'PID' = '0XA073'
19:36:36.245 > [VE.Direct MPPT 12/11] Text Data 'FW' = '164'
19:36:36.353 > [VE.Direct MPPT 12/11] Text Data 'SER' = 'HQ2-------------'
19:36:36.408 > [VE.Direct MPPT 12/11] Text Data 'V' = '53320'
19:36:36.470 > [VE.Direct MPPT 12/11] Text Data 'I' = '0'
19:36:36.524 > [VE.Direct MPPT 12/11] Text Data 'VPV' = '180'
19:36:36.579 > [VE.Direct MPPT 12/11] Text Data 'PPV' = '0'
19:36:36.648 > [VE.Direct MPPT 12/11] Text Data 'CS' = '0'
19:36:36.696 > [VE.Direct MPPT 12/11] Text Data 'MPPT' = '0'
19:36:36.743 > [VE.Direct MPPT 12/11] Text Data 'OR' = '0X00000001'
19:36:36.790 > [VE.Direct MPPT 12/11] Text Data 'ERR' = '0'
19:36:36.837 > [VE.Direct MPPT 12/11] Text Data 'LOAD' = 'ON'
19:36:36.884 > [VE.Direct MPPT 12/11] Text Data 'H19' = '5485'
19:36:36.931 > [VE.Direct MPPT 12/11] Text Data 'H20' = '90'
19:36:36.992 > [VE.Direct MPPT 12/11] Text Data 'H21' = '308'
19:36:37.054 > [VE.Direct MPPT 12/11] Text Data 'H22' = '79'
19:36:37.104 > [VE.Direct MPPT 12/11] Text Data 'H23' = '265'
19:36:37.164 > [VE.Direct MPPT 12/11] Text Data 'HSDS' = '47'
19:36:37.222 > [VE.Direct MPPT 12/11] Sending Hex Command: :727200007, Free FIFO-Buffer: 118
19:36:37.280 > [VE.Direct MPPT 12/11] Hex Data: Network total DC power value indicates non-networked controller
19:36:37.334 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDD5 (Charger Voltage), value: 0x000014D5, flags: 0x00
19:36:37.393 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDBB (Panel Voltage), value: 0x00000013, flags: 0x00
19:36:37.478 > [PowerMeterSerialSml] decoded energy import to -0.10
19:36:37.540 > [PowerMeterSerialSml] decoded energy import to 1514999.88
19:36:37.601 > [PowerMeterSerialSml] decoded energy export to -10.00
19:36:37.658 > [PowerMeterSerialSml] decoded energy export to 462664.91
19:36:37.711 > [PowerMeterSerialSml] decoded active power total to 404.00
19:36:37.769 > [PowerMeterSerialSml] decoded active power total to 404.00
19:36:37.884 > [PowerMeterSerialSml] TotalPower: 404.00
19:36:37.950 > [DPL::loop] ******************* ENTER **********************
19:36:38.001 > [DPL::loop] battery interface enabled, SoC: 99.0 %, StartTH: 90 %, StopTH: 20 %, SoC age: 3 s, ignore: no
19:36:38.048 > [DPL::getBatteryVoltage] BMS: 53.25 V, MPPT: 53.32 V, inverter 1164a-----------: 53.40 V, returning: 53.25V
19:36:38.095 > [DPL::loop] dcVoltage: 53.25 V, loadCorrectedVoltage: 53.25 V, StartTH: 53.00 V, StopTH: 49.00 V
19:36:38.152 > [DPL::loop] StartTH reached: yes, StopTH reached: no, SolarPT disabled, use at night: yes
19:36:38.214 > [DPL::calcHouseholdConsumption] target consumption: 0 W, base load: 10 W
19:36:38.282 > [DPL::calcHouseholdConsumption] power meter value: 404.0 W, power meter valid: yes
19:36:38.342 > [DPL::calcHouseholdConsumption] inverter 1164------------ is behind power meter producing 0 W
19:36:38.397 > [DPL::updateInverterLimits] requested: 404 W, producing: 0 W using 0 solar-powered inverters, diff: 404 W, hysteresis: 30 W
19:36:38.503 > [DPL::calcBatteryAllowance] power requested: 404 W
19:36:38.560 > [DPL::updateInverterLimits] requested: 404 W, producing: 0 W using 1 battery-powered inverters, diff: 404 W, hysteresis: 30 W
19:36:38.619 > [DPL::updateInverterLimits] will cover 0 W using battery-powered inverters
19:36:38.704 > [DPL inverter 1164--------------]:
19:36:38.755 >     battery-powered, producing 0 W
19:36:38.814 >     lower/current/upper limit: 10/0/500 W, output capability: 1600 W
19:36:38.883 >     sending commands enabled, reachable, disqualified
19:36:38.958 >     max reduction production/standby: 0/0 W, max increase: 0 W
19:36:39.006 >     target limit/output/state: -1 W (unchanged)/0 W/unchanged, 0 update timeouts
19:36:39.061 > [DPL::loop] consumption: 404 W, target output: 404 W (limited to 1500 W), solar inverters output: 0 W, battery allowance: 404 W, battery inverters output: 0 W
19:36:39.116 > [VE.Direct MPPT 12/11] serial input (227 Bytes):
19:36:39.163 > [VE.Direct MPPT 12/11] 3a 37 32 37 32 30 30 30 46 46 46 46 46 46 46 46
19:36:39.221 > [VE.Direct MPPT 12/11] 30 42 0a 3a 41 44 35 45 44 30 30 44 35 31 34 41
19:36:39.285 > [VE.Direct MPPT 12/11] 30 0a 3a 41 42 42 45 44 30 30 31 33 30 30 39 30
19:36:39.345 > [VE.Direct MPPT 12/11] 0a 0d 0a 50 49 44 09 30 78 41 30 37 33 0d 0a 46
19:36:39.412 > [VE.Direct MPPT 12/11] 57 09 31 36 34 0d 0a 53 45 52 23 09 48 51 32 32
19:36:39.468 > [VE.Direct MPPT 12/11] 34 38 48 39 41 34 33 0d 0a 56 09 35 33 33 33 30
19:36:39.626 > [VE.Direct MPPT 12/11] 0d 0a 49 09 30 0d 0a 56 50 56 09 31 38 30 0d 0a
19:36:39.691 > [VE.Direct MPPT 12/11] 50 50 56 09 30 0d 0a 43 53 09 30 0d 0a 4d 50 50
19:36:39.749 > [VE.Direct MPPT 12/11] 54 09 30 0d 0a 4f 52 09 30 78 30 30 30 30 30 30
19:36:39.835 > [VE.Direct MPPT 12/11] 30 31 0d 0a 45 52 52 09 30 0d 0a 4c 4f 41 44 09
19:36:39.886 > [VE.Direct MPPT 12/11] 4f 4e 0d 0a 48 31 39 09 35 34 38 35 0d 0a 48 32
19:36:39.942 > [VE.Direct MPPT 12/11] 30 09 39 30 0d 0a 48 32 31 09 33 30 38 0d 0a 48
19:36:39.999 > [VE.Direct MPPT 12/11] 32 32 09 37 39 0d 0a 48 32 33 09 32 36 35 0d 0a
19:36:40.139 > [VE.Direct MPPT 12/11] 48 53 44 53 09 34 37 0d 0a 43 68 65 63 6b 73 75
19:36:40.190 > [VE.Direct MPPT 12/11] 6d 09 f3
19:36:40.256 > [VE.Direct MPPT 12/11] Text Data 'PID' = '0XA073'
19:36:40.317 > [VE.Direct MPPT 12/11] Text Data 'FW' = '164'
19:36:40.374 > [VE.Direct MPPT 12/11] Text Data 'SER' = '------------'
19:36:40.420 > [VE.Direct MPPT 12/11] Text Data 'V' = '53330'
19:36:40.469 > [VE.Direct MPPT 12/11] Text Data 'I' = '0'
19:36:40.526 > [VE.Direct MPPT 12/11] Text Data 'VPV' = '180'
19:36:40.577 > [VE.Direct MPPT 12/11] Text Data 'PPV' = '0'
19:36:40.624 > [VE.Direct MPPT 12/11] Text Data 'CS' = '0'
19:36:40.673 > [VE.Direct MPPT 12/11] Text Data 'MPPT' = '0'
19:36:40.718 > [VE.Direct MPPT 12/11] Text Data 'OR' = '0X00000001'
19:36:40.774 > [VE.Direct MPPT 12/11] Text Data 'ERR' = '0'
19:36:40.836 > [VE.Direct MPPT 12/11] Text Data 'LOAD' = 'ON'
19:36:40.891 > [VE.Direct MPPT 12/11] Text Data 'H19' = '5485'
19:36:40.938 > [VE.Direct MPPT 12/11] Text Data 'H20' = '90'
19:36:40.986 > [VE.Direct MPPT 12/11] Text Data 'H21' = '308'
19:36:41.041 > [VE.Direct MPPT 12/11] Text Data 'H22' = '79'
19:36:41.103 > [VE.Direct MPPT 12/11] Text Data 'H23' = '265'
19:36:41.163 > [VE.Direct MPPT 12/11] Text Data 'HSDS' = '47'
19:36:41.230 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0x0201 (Device State), value: 0x00000000, flags: 0x00
19:36:41.294 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0x0200 (Device Mode), value: 0x00000001, flags: 0x00
19:36:41.363 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0x0202 (Remote Control Used), value: 0x00000002, flags: 0x00
19:36:41.414 > [VE.Direct MPPT 12/11] Sending Hex Command: :7F6ED006B, Free FIFO-Buffer: 118
19:36:41.582 > [VE.Direct MPPT 12/11] Hex Data: MPPT Float Voltage (0xEDF6): 54.00V
19:36:41.640 > [VE.Direct MPPT 12/11] Sending Hex Command: :727200007, Free FIFO-Buffer: 118
19:36:41.696 > [VE.Direct MPPT 12/11] Hex Data: Network total DC power value indicates non-networked controller
19:36:41.740 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDD5 (Charger Voltage), value: 0x000014D4, flags: 0x00
19:36:41.788 > [VE.Direct MPPT 12/11] Unhandled Hex Async Response, addr: 0xEDBB (Panel Voltage), value: 0x00000012, flags: 0x00
19:36:41.847 > [PowerMeterSerialSml] decoded energy import to -0.10
19:36:41.897 > [PowerMeterSerialSml] decoded energy import to 1515000.12
19:36:41.954 > [PowerMeterSerialSml] decoded energy export to -10.00
19:36:42.008 > [PowerMeterSerialSml] decoded energy export to 462664.91
19:36:42.064 > [PowerMeterSerialSml] decoded active power total to 407.00
19:36:42.124 > [PowerMeterSerialSml] decoded active power total to 407.00
19:36:42.192 > [PowerMeterSerialSml] TotalPower: 407.00
19:36:42.256 > [VE.Direct MPPT 12/11] serial input (287 Bytes):
19:36:42.306 > [VE.Direct MPPT 12/11] 3a 41 30 31 30 32 30 30 30 30 34 38 0a 3a 41 30
19:36:42.363 > [VE.Direct MPPT 12/11] 30 30 32 30 30 30 31 34 38 0a 3a 41 30 32 30 32
19:36:42.416 > [VE.Direct MPPT 12/11] 30 30 30 32 30 30 30 30 30 30 34 35 0a 3a 37 46
19:36:42.465 > [VE.Direct MPPT 12/11] 36 45 44 30 30 31 38 31 35 33 45 0a 3a 37 32 37
19:36:42.509 > [VE.Direct MPPT 12/11] 32 30 30 30 46 46 46 46 46 46 46 46 30 42 0a 3a
19:36:42.565 > [VE.Direct MPPT 12/11] 41 44 35 45 44 30 30 44 34 31 34 41 31 0a 3a 41
19:36:42.631 > [VE.Direct MPPT 12/11] 42 42 45 44 30 30 31 32 30 30 39 31 0a 0d 0a 50
19:36:42.691 > [VE.Direct MPPT 12/11] 49 44 09 30 78 41 30 37 33 0d 0a 46 57 09 31 36
19:36:42.749 > [VE.Direct MPPT 12/11] 34 0d 0a 53 45 52 23 09 48 51 32 32 34 38 48 39
19:36:42.796 > [VE.Direct MPPT 12/11] 41 34 33 0d 0a 56 09 35 33 33 33 30 0d 0a 49 09
Hier meine Pin-Map:
[
	{
    "name": "Inv.: HMS/T/HM; BMS: Pylon-CAN ; MPPT P: 2-3; OLED",
    "nrf24": {
		"miso": -1,
		"mosi": -1,
		"clk": -1,
		"irq": -1,
		"en": -1,
		"cs": -1
    },
    "cmt": {
		"clk": 6,
		"cs": 4,
		"fcs": 21,
		"sdio": 5,
		"gpio2": -1,
		"gpio3": -1
    },
    "led": {
		"led0": 2,
		"led1": 1
    },
    "display": {
		"type": 3,
		"data": 9,
		"clk": 8,
		"cs": -1,
		"reset": -1
    },
    "victron": {
		"rx": 12,
		"tx": 11,
		"rx1": 10,
		"tx1": 17
    },
	"battery": {
		"rx": 18,
		"tx": 7
	},
	"powermeter": {
		"tx": 39,
		"rx": 40,
		"dere": -1
	}
  },
  {
    "name": "Inv.: HMS/T/HM; BMS: Pylon-CAN ; MPPT P: 2-3; OLED; W5500",
    "nrf24": {
		"miso": -1,
		"mosi": -1,
		"clk": -1,
		"irq": -1,
		"en": -1,
		"cs": -1
    },
    "cmt": {
		"clk": 6,
		"cs": 4,
		"fcs": 21,
		"sdio": 5,
		"gpio2": -1,
		"gpio3": -1
    },
    "w5500": {
		"mosi": 35,
		"miso": 48,
		"sclk": 36,
		"cs": 37,
		"int": 47,
		"rst": 38
        },
    "led": {
		"led0": 2,
		"led1": 1
    },
    "display": {
		"type": 3,
		"data": 9,
		"clk": 8,
		"cs": -1,
		"reset": -1
    },
    "victron": {
		"rx": 12,
		"tx": 11,
		"rx1": 10,
		"tx1": 17
    },
	"battery": {
		"rx": 18,
		"tx": 7
	},
	"powermeter": {
		"tx": 39,
		"rx": 40,
		"dere": -1
	}
  }
]

Originally posted by @andy75andreas in #1409 (comment)

@schlimmchen
Copy link
Member Author

19:36:27.587 > [DPL inverter 1164a---------]:
19:36:27.641 >     battery-powered, producing 1 W
19:36:27.707 >     lower/current/upper limit: 10/0/500 W, output capability: 1600 W
19:36:27.771 >     sending commands enabled, reachable, disqualified
19:36:27.843 >     max reduction production/standby: 0/0 W, max increase: 0 W
19:36:27.899 >     target limit/output/state: -1 W (unchanged)/1 W/unchanged, 0 update timeouts

Der Inverter kann nicht verwendet werden, weil der DPL darauf wartet, dass bekannt wird, welches Limit dort eingestellt ist.

Hält dieser Zustand dauerhaft an oder nur fünf Minuten nach dem Start deiner OpenDTU-OnBattery?

Wie lang ist die Uptime/Betriebszeit laut Web UI unter Info -> System?

@schlimmchen schlimmchen changed the title [Bug] DPL: Inverter produziert nicht [Bug] DPL: Inverter produziert nicht: disqualified, current limit unknown Nov 26, 2024
@schlimmchen
Copy link
Member Author

@andy75andreas Ich habe dein Problem in dieses Issue verschoben. Bitte starte keine Diskussion um ein neues Problem in einem existierenden Issue. Neues Problem => neues Issue. Wenn ein Issue keins ist, machen wir es wieder zu, kein Problem. Die Ganzzahlen um Issues durchzunummerieren gehen uns sobald nicht aus. Wovon aber nicht genug da ist: Kapazität mehrere Themen in ein und dem gleichen Issue auseinander zu halten 😉

@andy75andreas
Copy link

Hallo "schlimmchen", alles klar und kein Problem.

Hier die Daten der Batterie:
Screenshot 2024-11-26 203840

Betriebszeit: 0 Tage 00:48:16

Dieser Zustand ist seit dem Update auf die aktuelle Version.
Es spiel im Übrigen auch keine Rolle ob der W5500 in den Einstellungen aktiviert ist oder nicht.

@schlimmchen
Copy link
Member Author

Hm. Im Live-View ist der Inverter gelb (nicht rot), oder sogar blau? Was sagt "Letzte Aktualisierung"?

Als Workaround kannst du bitte einmal ein beliebiges Limit manuell an den Inverter schicken, z.B. 100W, über die Web UI. Dann wird bekannt sein, dass 100W eingestellt sind, und der DPL kann diesen Inverter verwenden.

Was ich nicht verstehe ist, warum OpenDTU nicht irgendwann das Limit abfragt. Vielleicht wird nur ein Versuch pro Neustart unternommen, und wenn der fehlschlägt, bleibt das Limit unbekannt? Das müsste ich mal im Code nachlesen. Es erscheint mir aber nötig, das der DPL selbstständig nach einer gewissen Zeitspanne das lower power limit setzt, sodass das gesetzte Limit bekannt ist.

@andy75andreas
Copy link

andy75andreas commented Nov 26, 2024

Hallo,

manuell auf 10% eingestellt = 160W.
Und ab da Regelt der DPL automatisch.
Der Inverter war seit der Aktualisierung "blau" und hat 0W angezeigt.
Den Inverter hatte ich auch schon mal neugestartet.

Das war definitiv bei der vorherigen Version nicht so!

Screenshot 2024-11-26 205634

@schlimmchen
Copy link
Member Author

Das war definitiv bei der vorherigen Version nicht so!

Ja, ich weiß? Soll ich mich jetzt schämen?

Wenn du OpenDTU-OnBattery neu startest, kommt das Problem dann wieder und bleibt für mindestens fünf Minuten? Es dauert eine Zeit lang nach einem Neustart, aber nach fünf Minuten sollte es dann losgehen.

@andy75andreas
Copy link

Sollte keine Anschuldigung sein.

Nach Neustart:

Umrichter steht bei 0%, produziert aber 30W.
Umrichter bleibt bei 0%.
Manuell auf 10% und der DPL regelt.

Screenshot 2024-11-26 210255
Screenshot 2024-11-26 210544

@schlimmchen
Copy link
Member Author

Umrichter bleibt bei 0%.
Manuell auf 10% und der DPL regelt.

Hast du zwischen diesen beiden Schritten fünf Minuten verstreichen lassen?

Hm, ich glaube es ist egal, denn das ist schon mehrfach aufgefallen, und es ist jedenfalls Mist, wenn die OpenDTU-OnBattery neu startet und dann (aus ungeklärten Gründen) der DPL niemals anfängt zu regeln weil er darauf wartet zu erfahren, welches Limit eingestellt ist. Er muss im Zweifel selbst ein befehlen. Das werde ich einbauen.

@andy75andreas
Copy link

Noch ne Frage zur Regelung mit 2 WR.
Bei einem WR wird alle 5s ein Wert gesendet und bei 2 WR?
Ich habe zB meinen 2. WR der direkt an der Somme hängt in der Kommunikation vom DTU ausgeschaltet damit der nicht immer abgefragt wird. Einmal im Monat mache ich den kurz an um die Werte zu lagen.
Wenn das dann doppelt so lange dauert wäre dann eine Nulleispeisung überhaupt noch möglich, da das System dann viel zu träge wird?

@schlimmchen
Copy link
Member Author

Bei einem WR wird alle 5s ein Wert gesendet

Das kommt ganz auf deine Einstellungen an. Setzt das PowerMeter Intervall auf 1s (wenn du einen hast, der Polling macht) und setz das DTU Intervall auf 1s, dann kann der DPL auch häufiger als alle 5s ein neues Limit setzen, auch wenn ein zweiter WR abgefragt wird.

@andy75andreas
Copy link

Hallo,

SML sendet immer 1s (Optischer Leser).
DTU mit 2s geht.

@schlimmchen
Copy link
Member Author

Also mir ist das jetzt mindestens drei Mal passiert an meinem Test-Setup und jedes Mal hat sich das Problem nach spätestens fünf Minuten von selbst erledigt, weil dann doch das aktuelle Limit vom WR erfragt wurde. Merkwürdig. Aber auch fünf Minuten warten müssen ist nicht ideal, daher bekräftige ich nochmal, dass der DPL "einfach" das lower power limit setzen sollte, wenn er bemerkt, dass der inverter kein bekanntes limit meldet.

@mkneppe
Copy link

mkneppe commented Nov 28, 2024

Ich habe gerade umgestellt von einem kleinen DTU-Board auf das Fusion-Board und dabei auch die Firmware auf den aktuellen Stand gehoben.
Nun habe ich ein ähnliches Problem, wie hier bisher beschrieben, außer dass es bei mir immer wieder auftritt.
Nach einem Neustart ist das Limit auf 0. Wenn ich es manuell hochsetze, regelt die opendtu eine Weile und setzt dann das Limit wieder auf Null.
Eine Passage, wo dies passiert sieht wie folgt aus:

21:05:58.595 > [DPL::updateInverterLimits] requested: 600 W, producing: 589 W using 1 battery-powered inverters, diff: 11 W, hysteresis: 1 W
21:05:58.638 > [DPL::updateInverterLimits] will cover 589 W using battery-powered inverters
21:05:58.682 > [DPL inverter 114184229865]:
21:05:58.726 >     battery-powered, producing 589 W
21:05:58.776 >     lower/current/upper limit: 0/0/600 W, output capability: 600 W
21:05:58.829 >     sending commands enabled, reachable, disqualified
21:05:58.879 >     max reduction production/standby: 0/0 W, max increase: 0 W
21:05:58.929 >     target limit/output/state: -1 W (unchanged)/589 W/unchanged, 0 update timeouts
21:05:58.979 > [DPL::loop] consumption: 2604 W, target output: 600 W (limited to 600 W), solar inverters output: 0 W, battery allowance: 600 W, battery inverters output: 589 W
21:05:59.030 > RX Period End
21:05:59.095 > Success
21:05:59.145 > [DPL::announceStatus] waiting for sufficiently recent inverter data
21:05:59.191 > [PowerMeterHttpJson] New total: 2569.04
21:05:59.237 > Fetch inverter: 114184229865
21:05:59.280 > TX RealTimeRunData Channel: 40 --> 15 84 22 98 65 80 19 79 72 80 0B 00 67 48 CD 21 00 00 00 00 00 00 00 00 B7 AB 88 
21:05:59.324 > Interrupt received
21:05:59.369 > RX Channel: 23 --> 95 84 22 98 65 84 22 98 65 01 00 01 02 0C 00 0F 00 4D 02 0D 00 0C 00 3D 00 0E E9 | -80 dBm
21:05:59.414 > RX Period End
21:05:59.465 > Last missing
21:05:59.509 > Request retransmit: 2
21:05:59.555 > TX RequestFrame Channel: 61 --> 15 84 22 98 65 80 19 79 72 82 5E 
21:05:59.601 > RX Period End
21:05:59.648 > Last missing
21:05:59.692 > Request retransmit: 2
21:05:59.736 > TX RequestFrame Channel: 75 --> 15 84 22 98 65 80 19 79 72 82 5E 
21:05:59.780 > Interrupt received
21:05:59.826 > RX Channel: 23 --> 95 84 22 98 65 84 22 98 65 02 BC A7 00 0E 54 A2 01 27 00 FA 09 32 13 87 00 84 83 | -80 dBm
21:05:59.874 > RX Period End
21:05:59.921 > Last missing
21:05:59.968 > Request retransmit: 3
21:06:00.228 > TX RequestFrame Channel: 3 --> 15 84 22 98 65 80 19 79 72 83 5F 
21:06:00.273 > Interrupt received
21:06:00.319 > RX Channel: 3 --> 95 84 22 98 65 84 22 98 65 83 00 00 00 06 03 E8 00 AC 00 18 16 EC B5 | -80 dBm
21:06:00.363 > RX Period End
21:06:00.412 > Success
21:06:00.458 > [DPL::announceStatus] waiting for sufficiently recent power meter reading
21:06:00.501 > [PowerMeterHttpJson] New total: 2550.06
21:06:00.545 > [PowerMeterHttpJson] New total: 2537.48
21:06:00.592 > [DPL::loop] ******************* ENTER **********************
21:06:00.643 > [DPL::loop] battery interface disabled, SoC: 0.0 %, StartTH: 80 %, StopTH: 20 %, SoC age: 63 s, ignore: yes
21:06:00.690 > [DPL::getBatteryVoltage] BMS: -1.00 V, MPPT: -1.00 V, inverter 114184229865: 52.50 V, returning: 52.50V
21:06:00.740 > [DPL::loop] dcVoltage: 52.50 V, loadCorrectedVoltage: 52.50 V, StartTH: 50.00 V, StopTH: 48.50 V
21:06:00.784 > [DPL::loop] StartTH reached: yes, StopTH reached: no, SolarPT enabled, use at night: yes
21:06:00.832 > [DPL::calcHouseholdConsumption] target consumption: 0 W, base load: 100 W
21:06:00.881 > [DPL::calcHouseholdConsumption] power meter value: 2537.5 W, power meter valid: yes
21:06:00.925 > [DPL::calcHouseholdConsumption] inverter 114184229865 is behind power meter producing 13 W
21:06:00.976 > [DPL::updateInverterLimits] requested: 600 W, producing: 0 W using 0 solar-powered inverters, diff: 600 W, hysteresis: 1 W
21:06:01.030 > [DPL::calcBatteryAllowance] power requested: 600 W
21:06:01.073 > [DPL::updateInverterLimits] requested: 600 W, producing: 13 W using 1 battery-powered inverters, diff: 587 W, hysteresis: 1 W
21:06:01.125 > [DPL::updateInverterLimits] will cover 13 W using battery-powered inverters
21:06:01.169 > [DPL inverter 114184229865]:
21:06:01.215 >     battery-powered, producing 13 W
21:06:01.260 >     lower/current/upper limit: 0/0/600 W, output capability: 600 W
21:06:01.303 >     sending commands enabled, reachable, disqualified
21:06:01.386 >     max reduction production/standby: 0/0 W, max increase: 0 W
21:06:01.434 >     target limit/output/state: -1 W (unchanged)/13 W/unchanged, 0 update timeouts
21:06:01.511 > [DPL::loop] consumption: 2550 W, target output: 600 W (limited to 600 W), solar inverters output: 0 W, battery allowance: 600 W, battery inverters output: 13 W
21:06:01.558 > [DPL::announceStatus] the system is stable, the last power limit is still valid
21:06:01.603 > Admin AP remaining seconds: 60 / 180
21:06:01.649 > [DPL::loop] ******************* ENTER **********************
21:06:01.699 > [DPL::loop] battery interface disabled, SoC: 0.0 %, StartTH: 80 %, StopTH: 20 %, SoC age: 64 s, ignore: yes
21:06:01.741 > [DPL::getBatteryVoltage] BMS: -1.00 V, MPPT: -1.00 V, inverter 114184229865: 52.50 V, returning: 52.50V
21:06:01.788 > [DPL::loop] dcVoltage: 52.50 V, loadCorrectedVoltage: 52.50 V, StartTH: 50.00 V, StopTH: 48.50 V
21:06:01.832 > [DPL::loop] StartTH reached: yes, StopTH reached: no, SolarPT enabled, use at night: yes
21:06:01.877 > [DPL::calcHouseholdConsumption] target consumption: 0 W, base load: 100 W
21:06:01.921 > [DPL::calcHouseholdConsumption] power meter value: 2537.5 W, power meter valid: yes
21:06:01.966 > [DPL::calcHouseholdConsumption] inverter 114184229865 is behind power meter producing 13 W

Anschließend ist alles wieder auf 0 und ich muss das Limit manuell setzen. Das geschieht bei mir so ca. alle 2-3 Minuten.

@mkneppe
Copy link

mkneppe commented Nov 29, 2024

Ich habe mal in meinem iobroker addiert, dass immer wenn der DPL das Limit auf 0 setzt, dass er wieder auf 100 % setzt.

2024-11-29 09:16:42.557 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt
2024-11-29 09:21:45.373 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt
2024-11-29 09:31:42.337 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt
2024-11-29 09:36:43.342 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt
2024-11-29 09:41:42.332 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt
2024-11-29 09:46:43.370 - warn: javascript.0 (2180) script.js.BKW.openDTU_Ausgleichen: 100 % wegen 0 gesetzt

Es ist immer ein vielfaches der genannten 5 Minuten.
Kann das ein Konfigurationsfehler von meiner Seite sein ?
Innerhalb der 5 Minuten regelt er korrekt. Nach den 5 Minuten stellt die "opendtu on battery" den WR wieder auf 0

schlimmchen added a commit that referenced this issue Nov 30, 2024
when starting up, the current limit set at the inverter is not known for
a couple of minutes (see upstream FAQ). to speed things up and to make
sure that the current limit is eventually known (which it is not always,
see #1427), the DPL now sends the lower power limit proactively.
@schlimmchen
Copy link
Member Author

Erledigt in be9e2aa.

Copy link

github-actions bot commented Jan 1, 2025

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new discussion or issue for related concerns.

@github-actions github-actions bot locked as resolved and limited conversation to collaborators Jan 1, 2025
Sign up for free to subscribe to this conversation on GitHub. Already have an account? Sign in.
Labels
None yet
Projects
None yet
Development

No branches or pull requests

3 participants