See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -6.5dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.5 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 190 Hz | 0.46 | -5.2 dB |
Peaking | 1638 Hz | 1.92 | -12.0 dB |
Peaking | 1893 Hz | 0.58 | 8.7 dB |
Peaking | 4044 Hz | 2.72 | 2.7 dB |
Peaking | 6085 Hz | 6.02 | 3.2 dB |
Peaking | 17 Hz | 1.55 | 1.5 dB |
Peaking | 1961 Hz | 4.89 | -1.8 dB |
Peaking | 2488 Hz | 2.29 | 2.0 dB |
Peaking | 2942 Hz | 3.84 | -1.6 dB |
Peaking | 19336 Hz | 0.61 | -3.8 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -7.4dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | 0.9 dB |
Peaking | 62 Hz | 1.41 | -2.1 dB |
Peaking | 125 Hz | 1.41 | -3.5 dB |
Peaking | 250 Hz | 1.41 | -4.4 dB |
Peaking | 500 Hz | 1.41 | -0.4 dB |
Peaking | 1000 Hz | 1.41 | 1.5 dB |
Peaking | 2000 Hz | 1.41 | -1.1 dB |
Peaking | 4000 Hz | 1.41 | 7.3 dB |
Peaking | 8000 Hz | 1.41 | 0.7 dB |
Peaking | 16000 Hz | 1.41 | -2.5 dB |