Skip to content

Latest commit

 

History

History
 
 

Beyerdynamic DT 48

See usage instructions for more options and info.

Parametric EQs

In case of using parametric equalizer, apply preamp of -7.2dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -7.4 dB.

Type Fc Q Gain
Peaking 46 Hz 0.51 14.5 dB
Peaking 76 Hz 0.83 -17.4 dB
Peaking 553 Hz 2.57 6.7 dB
Peaking 5273 Hz 1.85 9.0 dB
Peaking 19242 Hz 0.27 -15.6 dB
Peaking 778 Hz 1.22 3.5 dB
Peaking 1789 Hz 0.71 -7.9 dB
Peaking 3758 Hz 1.24 5.8 dB
Peaking 5064 Hz 4.69 -3.0 dB
Peaking 8779 Hz 3.58 1.3 dB

Fixed Band EQs

In case of using fixed band (also called graphic) equalizer, apply preamp of -8.5dB (if available) and set gains manually with these parameters.

Type Fc Q Gain
Peaking 31 Hz 1.41 9.2 dB
Peaking 62 Hz 1.41 -3.6 dB
Peaking 125 Hz 1.41 -4.2 dB
Peaking 250 Hz 1.41 -1.4 dB
Peaking 500 Hz 1.41 6.5 dB
Peaking 1000 Hz 1.41 -0.9 dB
Peaking 2000 Hz 1.41 -8.3 dB
Peaking 4000 Hz 1.41 8.5 dB
Peaking 8000 Hz 1.41 0.7 dB
Peaking 16000 Hz 1.41 -19.8 dB

Graphs