See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -3.3dB and build filters manually with these parameters. The first 4 filters can be used independently. When using independent subset of filters, apply preamp of -3.4 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 346 Hz | 1.71 | 3.1 dB |
Peaking | 661 Hz | 3.15 | 2.4 dB |
Peaking | 6297 Hz | 1.47 | -3.7 dB |
Peaking | 20258 Hz | 0.24 | -3.2 dB |
Peaking | 20 Hz | 1.42 | 2.6 dB |
Peaking | 49 Hz | 0.92 | -2.0 dB |
Peaking | 1038 Hz | 4.65 | -1.2 dB |
Peaking | 2853 Hz | 3.88 | -1.8 dB |
Peaking | 4083 Hz | 7.29 | 2.3 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -3.3dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | -0.1 dB |
Peaking | 62 Hz | 1.41 | -1.9 dB |
Peaking | 125 Hz | 1.41 | -0.1 dB |
Peaking | 250 Hz | 1.41 | 1.5 dB |
Peaking | 500 Hz | 1.41 | 2.9 dB |
Peaking | 1000 Hz | 1.41 | -0.6 dB |
Peaking | 2000 Hz | 1.41 | 0.1 dB |
Peaking | 4000 Hz | 1.41 | -1.2 dB |
Peaking | 8000 Hz | 1.41 | -3.0 dB |
Peaking | 16000 Hz | 1.41 | -2.6 dB |