See usage instructions for more options and info.
In case of using parametric equalizer, apply preamp of -6.5dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.5 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 25 Hz | 0.88 | 6.3 dB |
Peaking | 3227 Hz | 3.43 | -2.5 dB |
Peaking | 4190 Hz | 6.2 | 3.7 dB |
Peaking | 9702 Hz | 1.43 | 3.3 dB |
Peaking | 19499 Hz | 0.42 | -11.3 dB |
Peaking | 60 Hz | 2.11 | 1.0 dB |
Peaking | 180 Hz | 0.86 | -1.9 dB |
Peaking | 573 Hz | 1.18 | 1.1 dB |
Peaking | 5959 Hz | 5.4 | -3.9 dB |
Peaking | 6591 Hz | 2.48 | 2.0 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -6.9dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | 6.5 dB |
Peaking | 62 Hz | 1.41 | 1.0 dB |
Peaking | 125 Hz | 1.41 | -1.3 dB |
Peaking | 250 Hz | 1.41 | -1.5 dB |
Peaking | 500 Hz | 1.41 | 1.1 dB |
Peaking | 1000 Hz | 1.41 | 0.2 dB |
Peaking | 2000 Hz | 1.41 | -0.4 dB |
Peaking | 4000 Hz | 1.41 | -0.2 dB |
Peaking | 8000 Hz | 1.41 | 2.2 dB |
Peaking | 16000 Hz | 1.41 | -8.3 dB |