% Filename: designPars.m
% Description: Loads design parameters for the hyperloop_arc model
% Copyright 2013 - 2014 The MathWorks, Inc
%% Tube
Tube.tempAmbient = 293; % 20 C
Tube.pressureAmbient = 100; % 100 Pascals referenced on page 12 (Pa)
Tube.powerTube = -3e6; % guess for pumps and other tube side power requirements(W)
Tube.powerGridMax = 6e6; % max grid power is 6MW from page 35
Tube.powerSolar = 6e6; % peak solar power is defined as 285MW on
% page 35. This seems high given the power
% capacity of other components. Assume 6 MW
% for now.
Tube.energyStorage = 36e6*60*60; % 36 MWhr on page 35 (W-s)
%% Chassis
Chassis.Mass = 15e3; % (kg)
Chassis.DragCoeff = 320/1130; % 1130 km/h causes 320 N of friction (N/kph)
Chassis.Height = 1.1; % (m)
Chassis.Width = 1.35; % (m)
Chassis.TubeRadius = 1.15; % (m)
%% Propulsion
Prop.MaxForce = 15e3*9.81;% (N) capable of 1 g accel on page 32;
%% Suspension
Suspension.ChassisMass = 15e3; % (kg)
%% Power
Power.MaxEnergy = 5*85e3*60*60; % (W-s)
% Model S is ~500kg for 85 kWh.
% Page 22 talks about 2500 kg of
% batteries, so that's roughly 5x85 kWh
Power.Efficiency = 0.98; % (0-1) assumption for bi-directional
% efficiency in and out of battery
%% Compressor
Comp.CoolantTemp = 293; % (K)
Comp.CoolantFlow = 0.14; % (kg/sec)
Comp.CoolantMass = 290; % (kg)
Comp.Comp1Ratio = 21;
Comp.IC1OutletTemp = 300; % (K)
Comp.FlowToSusp = 0.2; % (kg/sec)
Comp.Comp2Ratio = 5.2;
Comp.IC2OutletTemp = 400; % (K)