forked from AchimKre/venus.dbus-tasmota-smartmeter
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathdbus-tasmota-smartmeter.py
182 lines (152 loc) · 8.24 KB
/
dbus-tasmota-smartmeter.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
#!/usr/bin/env python
##########################
# adapt form
# juf
# and
# fabian-lauer / dbus-shelly-3em-smartmeter
# and
# RalfZim / venus.dbus-fronius-smartmeter
##########################################
# import normal packages
import platform
import logging
import sys
import os
import sys
if sys.version_info.major == 2:
import gobject
else:
from gi.repository import GLib as gobject
import sys
import time
import requests # for http GET
# our own packages from victron
sys.path.insert(1, os.path.join(os.path.dirname(__file__), '/opt/victronenergy/dbus-systemcalc-py/ext/velib_python'))
from vedbus import VeDbusService
class DbusSmartmeterService:
def __init__(self, servicename, deviceinstance, paths, productname='Tasmota', connection='Tasmota Web service'):
self._dbusservice = VeDbusService("{}.http_{:02d}".format(servicename, deviceinstance))
self._paths = paths
logging.debug("%s /DeviceInstance = %d" % (servicename, deviceinstance))
# Create the management objects, as specified in the ccgx dbus-api document
self._dbusservice.add_path('/Mgmt/ProcessName', __file__)
self._dbusservice.add_path('/Mgmt/ProcessVersion', 'Unkown version, and running on Python ' + platform.python_version())
self._dbusservice.add_path('/Mgmt/Connection', connection)
# Create the mandatory objects
self._dbusservice.add_path('/DeviceInstance', deviceinstance)
self._dbusservice.add_path('/ProductId', 45069) # found on https://www.sascha-curth.de/projekte/005_Color_Control_GX.html#experiment - should be an ET340 Engerie Meter
self._dbusservice.add_path('/DeviceType', 345) # found on https://www.sascha-curth.de/projekte/005_Color_Control_GX.html#experiment - should be an ET340 Engerie Meter
self._dbusservice.add_path('/ProductName', productname)
self._dbusservice.add_path('/CustomName', productname)
self._dbusservice.add_path('/Latency', None)
self._dbusservice.add_path('/FirmwareVersion', 0.1)
self._dbusservice.add_path('/HardwareVersion', 0)
self._dbusservice.add_path('/Connected', 1)
self._dbusservice.add_path('/Role', 'grid')
self._dbusservice.add_path('/Position', 0) # normaly only needed for pvinverter
self._dbusservice.add_path('/UpdateIndex', 0)
# add path values to dbus
for path, settings in self._paths.items():
self._dbusservice.add_path(
path, settings['initial'], gettextcallback=settings['textformat'], writeable=True, onchangecallback=self._handlechangedvalue)
# last update
self._lastUpdate = 0
# add _update function 'timer'
gobject.timeout_add(250, self._update) # pause 250ms before the next request
# add _signOfLife 'timer' to get feedback in log every 5minutes
gobject.timeout_add(1000, self._update)
def _update(self):
try:
meter_url = "http://192.168.XXX.XXX/cm?cmnd=status%2010"
meter_r = requests.get(url=meter_url) # request data from the Tasmota Smartmeter
meter_data = meter_r.json() # convert JSON data
#meter_consumption = meter_data['StatusSNS']['MT681']['DJ_TPWRCURR']['DJ_TPWRIN']['DJ_TPWROUT']
#send data to DBus
self._dbusservice['/Ac/Power'] = meter_data['StatusSNS']['MT681']['Power_cur'] # positive: consumption, negative: feed into grid
self._dbusservice['/Ac/Current'] = float(meter_data['StatusSNS']['MT681']['Power_cur'] / 230 )
self._dbusservice['/Ac/L1/Voltage'] = 230
#self._dbusservice['/Ac/L2/Voltage'] = 230
#self._dbusservice['/Ac/L3/Voltage'] = 230
self._dbusservice['/Ac/L1/Current'] = float(meter_data['StatusSNS']['MT681']['Power_cur'] / 230 )
#self._dbusservice['/Ac/L2/Current'] = 1
#self._dbusservice['/Ac/L3/Current'] = 1
self._dbusservice['/Ac/L1/Power'] = float(meter_data['StatusSNS']['MT681']['Power_cur'])
#self._dbusservice['/Ac/L2/Power'] = 59
#self._dbusservice['/Ac/L3/Power'] = 59
self._dbusservice['/Ac/L1/Energy/Forward'] = meter_data['StatusSNS']['MT681']['Total_in']
#self._dbusservice['/Ac/L2/Energy/Forward'] = 0.059
#self._dbusservice['/Ac/L3/Energy/Forward'] = 0.059
self._dbusservice['/Ac/L1/Energy/Reverse'] = meter_data['StatusSNS']['MT681']['Total_out']
self._dbusservice['/Ac/Energy/Forward'] = self._dbusservice['/Ac/L1/Energy/Forward']
self._dbusservice['/Ac/Energy/Reverse'] = self._dbusservice['/Ac/L1/Energy/Reverse']
#logging
logging.debug("House Consumption (/Ac/Power): %s" % (self._dbusservice['/Ac/Power']))
logging.debug("House Forward (/Ac/Energy/Forward): %s" % (self._dbusservice['/Ac/Energy/Forward']))
logging.debug("House Reverse (/Ac/Energy/Revers): %s" % (self._dbusservice['/Ac/Energy/Reverse']))
logging.debug("---");
# increment UpdateIndex - to show that new data is available
index = self._dbusservice['/UpdateIndex'] + 1 # increment index
if index > 255: # maximum value of the index
index = 0 # overflow from 255 to 0
self._dbusservice['/UpdateIndex'] = index
#update lastupdate vars
self._lastUpdate = time.time()
except Exception as e:
logging.critical('Error at %s', '_update', exc_info=e)
# return true, otherwise add_timeout will be removed from GObject - see docs http://library.isr.ist.utl.pt/docs/pygtk2reference/gobject-functions.html#function-gobject--timeout-add
return True
def _handlechangedvalue(self, path, value):
logging.debug("someone else updated %s to %s" % (path, value))
return True # accept the change
def main():
#configure logging
logging.basicConfig( format='%(asctime)s,%(msecs)d %(name)s %(levelname)s %(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=logging.INFO,
handlers=[
logging.FileHandler("%s/current.log" % (os.path.dirname(os.path.realpath(__file__)))),
logging.StreamHandler()
])
try:
logging.info("Start");
from dbus.mainloop.glib import DBusGMainLoop
# Have a mainloop, so we can send/receive asynchronous calls to and from dbus
DBusGMainLoop(set_as_default=True)
#formatting
_kwh = lambda p, v: (str(round(v, 2)) + 'KWh')
_a = lambda p, v: (str(round(v, 1)) + 'A')
_w = lambda p, v: (str(round(v, 1)) + 'W')
_v = lambda p, v: (str(round(v, 1)) + 'V')
#start our main-service
pvac_output = DbusSmartmeterService(
servicename='com.victronenergy.grid',
deviceinstance=40,
paths={
'/Ac/Energy/Forward': {'initial': 0, 'textformat': _kwh}, # energy bought from the grid
'/Ac/Energy/Reverse': {'initial': 0, 'textformat': _kwh}, # energy sold to the grid
'/Ac/Power': {'initial': 0, 'textformat': _w},
'/Ac/Current': {'initial': 0, 'textformat': _a},
'/Ac/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L2/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L3/Voltage': {'initial': 0, 'textformat': _v},
'/Ac/L1/Current': {'initial': 0, 'textformat': _a},
'/Ac/L2/Current': {'initial': 0, 'textformat': _a},
'/Ac/L3/Current': {'initial': 0, 'textformat': _a},
'/Ac/L1/Power': {'initial': 0, 'textformat': _w},
'/Ac/L2/Power': {'initial': 0, 'textformat': _w},
'/Ac/L3/Power': {'initial': 0, 'textformat': _w},
'/Ac/L1/Energy/Forward': {'initial': 0, 'textformat': _kwh},
'/Ac/L2/Energy/Forward': {'initial': 0, 'textformat': _kwh},
'/Ac/L3/Energy/Forward': {'initial': 0, 'textformat': _kwh},
'/Ac/L1/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
'/Ac/L2/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
'/Ac/L3/Energy/Reverse': {'initial': 0, 'textformat': _kwh},
})
logging.info('Connected to dbus, and switching over to gobject.MainLoop() (= event based)')
mainloop = gobject.MainLoop()
mainloop.run()
except Exception as e:
logging.critical('Error at %s', 'main', exc_info=e)
if __name__ == "__main__":
main()