Temperature sensor as part of the TechnicMediumHub
.
Type: Hub Device
Status: Well Defined
Reports the current temperature of the device
Direction: Input
DataType: Int16 representing °C with one decimal place.
- Why there are two temperature sensors in
TechnicMediumHub
only diffing by parallel installation? Old/New Software for Testing purposes? 1
Binary Export
0B-00-43-60-01-02-01-01-00-00-00
05-00-43-60-02
11-00-44-60-00-00-54-45-4D-50-00-00-00-00-00-00-00
0E-00-44-60-00-01-00-00-61-C4-00-00-61-44
0E-00-44-60-00-02-00-00-C8-C2-00-00-C8-42
0E-00-44-60-00-03-00-00-B4-C2-00-00-B4-42
0A-00-44-60-00-04-44-45-47-00
08-00-44-60-00-05-50-00
0A-00-44-60-00-80-01-01-05-01
Human Readable Interpretation
Port: 96
IOTypeId: TechnicMediumHubTemperatureSensor
HardwareRevision: 0.0.0.1
SoftwareRevision: 0.0.0.1
OutputCapability: False
InputCapability: True
LogicalCombinableCapability: False
LogicalSynchronizableCapability: False
ModeCombinations: []
UsedCombinationIndex: 0
MultiUpdateEnabled: False
ConfiguredModeDataSetIndex: []
Mode: 0
Name: TEMP
IsInput: True
IsOutput: False
RawMin: -900
RawMax: 900
PctMin: -100
PctMax: 100
SIMin: -90
SIMax: 90
Symbol: DEG
InputSupportsNull: False
InputSupportFunctionalMapping20: True
InputAbsolute: True
InputRelative: False
InputDiscrete: False
OutputSupportsNull: False
OutputSupportFunctionalMapping20: False
OutputAbsolute: False
OutputRelative: False
OutputDiscrete: False
NumberOfDatasets: 1
DatasetType: Int16
TotalFigures: 5
Decimals: 1
DeltaInterval: 0
NotificationEnabled: False
Binary Export
0B-00-43-3D-01-02-01-01-00-00-00
05-00-43-3D-02
11-00-44-3D-00-00-54-45-4D-50-00-00-00-00-00-00-00
0E-00-44-3D-00-01-00-00-61-C4-00-00-61-44
0E-00-44-3D-00-02-00-00-C8-C2-00-00-C8-42
0E-00-44-3D-00-03-00-00-B4-C2-00-00-B4-42
0A-00-44-3D-00-04-44-45-47-00
08-00-44-3D-00-05-50-00
0A-00-44-3D-00-80-01-01-05-01
Human Readable Interpretation
Port: 61
IOTypeId: TechnicMediumHubTemperatureSensor
HardwareRevision: 1.0.0.0
SoftwareRevision: 1.0.0.0
OutputCapability: False
InputCapability: True
LogicalCombinableCapability: False
LogicalSynchronizableCapability: False
ModeCombinations: []
UsedCombinationIndex: 0
MultiUpdateEnabled: False
ConfiguredModeDataSetIndex: []
Mode: 0
Name: TEMP
IsInput: True
IsOutput: False
RawMin: -900
RawMax: 900
PctMin: -100
PctMax: 100
SIMin: -90
SIMax: 90
Symbol: DEG
InputSupportsNull: False
InputSupportFunctionalMapping20: True
InputAbsolute: True
InputRelative: False
InputDiscrete: False
OutputSupportsNull: False
OutputSupportFunctionalMapping20: False
OutputAbsolute: False
OutputRelative: False
OutputDiscrete: False
NumberOfDatasets: 1
DatasetType: Int16
TotalFigures: 5
Decimals: 1
DeltaInterval: 0
NotificationEnabled: False