Lost Connection to Hoymiles 2000 #1313

Closed
utna666 opened this issue Sep 5, 2023 · 7 comments
Closed

Lost Connection to Hoymiles 2000 #1313

utna666 opened this issue Sep 5, 2023 · 7 comments
Labels
bug Something isn't working

Comments

@utna666
Copy link

utna666 commented Sep 5, 2023

What happened?

I have 2 Hoymiles 2000 Inverter installed and they worked fine but today the OpenDTU lost Connection to both Inverters and now my Limit is set to 0%.

Both Inverters worked fine for the last 2 Days but now none of them are working anymore.

To Reproduce Bug

dont know

Expected Behavior

dont know

Install Method

Pre-Compiled binary from GitHub

What git-hash/version of OpenDTU?

v23.8.22

Relevant log/trace output

17:58:31.091 > RX Period End
17:58:31.091 > All missing
17:58:31.091 > Nothing received, resend count exeeded
17:58:31.234 > TX ActivePowerControl 865.00 MHz --> 51 74 90 43 89 80 10 10 52 81 0B 00 06 D6 00 00 10 E0 07 
17:58:31.290 > Interrupt received
17:58:31.336 > RX 865.00 MHz --> D1 74 90 43 89 80 10 10 52 81 00 00 0B 00 14 07 B4 | -63 dBm
17:58:34.496 > RX Period End
17:58:34.496 > Success
17:58:34.635 > TX ActivePowerControl 865.00 MHz --> 51 74 90 43 89 80 10 10 52 81 0B 00 09 92 00 00 11 A3 0E 
17:58:36.001 > Interrupt received
17:58:36.146 > RX 865.00 MHz --> D1 74 90 43 89 80 10 10 52 81 00 00 0B 00 14 07 B4 | -62 dBm
17:58:36.195 > RX Period End
17:58:36.195 > Success
17:58:36.258 > TX ActivePowerControl 865.00 MHz --> 51 81 03 61 96 80 10 10 52 81 0B 00 0E B0 00 00 6F 02 AF

Anything else?

No response

@utna666 utna666 added the bug Something isn't working label Sep 5, 2023
@tbnobody
Copy link
Owner

tbnobody commented Sep 5, 2023

But your log shows that the inverter gets a successfull ActivePowerControl command.... But every 5 seconds is way to fast.... if you flood the command queue with packages no stats request will be sent.

@utna666
Copy link
Author

utna666 commented Sep 5, 2023

But your log shows that the inverter gets a successfull ActivePowerControl command.... But every 5 seconds is way to fast.... if you flood the command queue with packages no stats request will be sent.

ive set it to 10 sec now but same error

@tbnobody
Copy link
Owner

tbnobody commented Sep 5, 2023

ive set it to 10 sec now but same error

Much to fast... Try 30 seconds at least....
this was already discussed several times... see #1088

@utna666
Copy link
Author

utna666 commented Sep 5, 2023

Ok i will try and send u tomorrow what has happend. Ty for your help

@broth-itk
Copy link
Contributor

Why is it even possible to set such low values without a warning or note of any type?

@tbnobody
Copy link
Owner

Closed due to inactivity

@tbnobody tbnobody closed this as not planned Won't fix, can't repro, duplicate, stale Mar 21, 2024
Copy link

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new discussion or issue for related concerns.