Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

S100102 and PCB v2B not working #822

Open
rclarke87 opened this issue Mar 2, 2025 · 1 comment
Open

S100102 and PCB v2B not working #822

rclarke87 opened this issue Mar 2, 2025 · 1 comment

Comments

@rclarke87
Copy link

rclarke87 commented Mar 2, 2025

Pump controller not lit or responding to button presses

Issue

The pump controller unit is completely unresponsive:

  • No LED indicators
  • No beep sounds
  • ESP powered, but WebUI fails to detect hardware, temp reading reads [abc]

Hardware Details

  • Model: S100102 pump - 2021 Vegas Air model (6-wire)
  • PCB Version: v2B
  • Configuration set to MIAMI2021 in hardware config

Troubleshooting Steps Completed

  1. Verified and resoldered all connections (continuity confirmed with multimeter)
  2. Tested with both H1A, and H1B configuration using 220pF ceramic capacitors and 560Ω resistors
  3. Tried multiple hardware configuration settings, including those recommended for this model

Questions

  1. The manual recommends 510Ω resistors for S100102 - would this potentially resolve the issue?
  2. Are there additional diagnostic steps recommended before ordering new components?
@visualapproach
Copy link
Owner

Hi,

  1. Not sure if it will make a difference.
  2. Yes. You can run the hardware test. Easiest to reach from UI Menu/directory, the click on "links.html".
    There is also some other features like .../inputs/ but it's more difficult to interpret the results from. You can post it here but and I can take a look.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment