daavid00
Copy link
Collaborator

We use RSSAT (RSWSAT for a gas water system) in the computation of convection (Eq. 17 in the benchmark description). To compute this way in a water gas system, one needs to build a version of OPM Flow after this commit. Before this commit the max solubility limit was a scalar computed over all time steps inside box C, while now using RSSAT (RSWSAT) this is computed per cell per time step, resulting in lower values of M.

@daavid00 daavid00 merged commit 5e54a42 into OPM:main Jul 18, 2024
1 check passed