ESPHome APsystems ECU Component

This repository adds support for inverters from APsystems to ESPHome. For the communication with the inverters you need to connect a cc2530 or a cc2531 zigbee module with a custom firmware.

Thanks

First of all I need to thank some people for their work in making this project possible:

  • @patience4711 for their work on various projects related to communication with APsystems inverters. Especially on ESP32-read-APS-inverters which served as a base for this project
  • @mampfes for their excellent esphome d0_obis custom_component, which also served as a base for this project.

Configuration

This component can easily be added as an external component to your ESPHome configuration.

Communication with the zigbee coordinator is done using UART, so you need to configure the UART bus. You also need to configure the time component, which is used to reset the daily energy at midnight.

Additionally you need to flash a custom firmware to the zigbee coordinator. For details see the next chapters.

external_components:
  - source: github://derrohrbach/esphome-apsystems

time:
  - platform: homeassistant

uart:
  rx_pin: 16
  tx_pin: 17
  baud_rate: 115200

apsystems:
  id: aps1
  coordinator_reset_pin: 5
  restore: true
  update_interval: 15s
  #auto_pair: false

sensor:
  - platform: apsystems
    serial: "[YOUR INVERTER SERIAL]"
    type: yc600
    #pair_id: "3CA1" #can be used if restore is set to false. pair id will be logged when pairing the inverter
    panels: 
      connected: [true, true] #can have up to 4 entries
      power: 
        name: "Solar Leistung Panel"
      energy:
        name: "Solar Energie Panel"
    power: 
      name: "Solar Leistung Gesamt"
    dc_power: 
      name: "Solar DC Leistung Gesamt"
    energy: 
      name: "Solar Energie Gesamt"
    temperature:
      name: "Solar Inverter Temperatur"

# Enable Home Assistant API
api:
  services:
    - service: pair_inverter    
      variables:
        serial: string
      then:
        - apsystems.pair_inverter:
            id: aps1
            serial: !lambda 'return serial;'
    - service: poll_inverter    
      variables:
        serial: string
      then:
        - apsystems.poll_inverter:
            id: aps1
            serial: !lambda 'return serial;'

Configuration Variables

APsystems platform

  • id (Optional, ID): Manually specify the ID used for code generation.
  • uart_id (Optional, ID): ID of the UART Component if you want to use multiple UART buses.
  • update_interval (Optional, string): How often the inverters should be polled
  • coordinator_reset_pin (Required, Pin): Pin which is connected to the reset pin of the zigbee coordinator
  • restore (Optional, bool): Specifies whether the daily energy production and inverter pair ids should be saved to the esp storage
  • auto_pair (Optional, bool): Specified if unpaired inverter should be automaticcally paired on first boot. Otherwise use the apsystems.pair_inverter command

Sensor

  • serial (Required, string): Serial number of your inverter (12 digits 0-9)
  • type (Required, string): Type of your inverter. Can be: "yc600", "qs1", "ds3"
  • pair_id (Optional, string): Pairing code of your inverter. Can be found in the log after pairing the inverter. Not neccessary if restore is on, since it is automatically saved to flash
  • panels (Required, object): Connected panels and per panel sensors
    • connected (Required, bool[]): Array of booleans. [true, false, true, false] means panels 1 and 3 are connected.
    • energy (Optional, Sensor): Configuration of ac energy sensor
    • power (Optional, Sensor): Configuration of ac power sensor
    • dc_power (Optional, Sensor): Configuration of dc power sensor
    • dc_voltage (Optional, Sensor): Configuration of dc voltage sensor
    • dc_current (Optional, Sensor): Configuration of dc current sensor
  • energy (Optional, Sensor): Configuration of ac energy sensor
  • power (Optional, Sensor): Configuration of ac power sensor
  • voltage (Optional, Sensor): Configuration of ac voltage sensor
  • frequency (Optional, Sensor): Configuration of ac frequency sensor
  • signal_strength (Optional, Sensor): Configuration of rf signal strength percent sensor
  • dc_power (Optional, Sensor): Configuration of dc power sensor

Hardware

A zigbee coordinator with custom firmware is required to use this component. Please refer to the documentation of ESP32-read-APS-inverters on how to flash this coordinator and connect it to your esp.

Note!

This was only tested with the following setups. If you can get it running on other setups then please let me know!

  • @derrohrbach
    • 1x YC600
    • ESP32 and ESP8266
    • cc2531 ZigBee Module flashed using ccloader

About

APsystems ECU for ESPHome with support for YC600, QS1, DS3

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • C++ 83.3%
  • Python 16.7%