-
Notifications
You must be signed in to change notification settings - Fork 2
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
1 parent
1ee4b33
commit e66ed97
Showing
4 changed files
with
693 additions
and
67 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,340 @@ | ||
### When different technology configurations or alternatives are found, | ||
### we are taking the best performing technology in terms of GWP. | ||
Wind: ### Check if IAMs make the distinction between onshore and offshore | ||
onshore: | ||
- name: electricity production, wind, <1MW turbine, onshore | ||
reference product: electricity, high voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.96 | ||
2050: | ||
min: 0.83 | ||
max: 0.96 | ||
distribution: uniform | ||
create copy: False | ||
offshore: | ||
- name: electricity production, wind, 1-3MW turbine, offshore | ||
reference product: electricity, high voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.04 | ||
2050: | ||
min: 0.04 | ||
max: 0.17 | ||
distribution: uniform | ||
create copy: False | ||
PV: | ||
c-Si: | ||
- name: electricity production, photovoltaic, at 93 kWp slanted-roof, multi-Si, laminated, integrated | ||
reference product: electricity production, photovoltaic, at 93 kWp slanted-roof, multi-Si, laminated, integrated | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.9440 | ||
2050: | ||
min: 0.6250 | ||
max: 0.9440 | ||
distribution: uniform | ||
create copy: False | ||
CdTe: | ||
- name: electricity production, photovoltaic, at 3kWp slanted-roof, CdTe, panel, mounted | ||
reference product: electricity production, photovoltaic, at 3kWp slanted-roof, CdTe, panel, mounted | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.0400 | ||
2050: | ||
min: 0.0400 | ||
max: 0.2500 | ||
distribution: uniform | ||
create copy: False | ||
CIGS: | ||
- name: electricity production, photovoltaic, 3kWp slanted-roof installation, CdTe, laminated, integrated | ||
reference product: electricity, low voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.015 | ||
2050: | ||
min: 0.015 | ||
max: 0.1250 | ||
distribution: uniform | ||
create copy: False | ||
a-Si: | ||
- name: electricity production, photovoltaic, 3kWp slanted-roof installation, a-Si, laminated, integrated | ||
reference product: electricity, low voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.0010 | ||
2050: | ||
min: 0.0000 | ||
max: 0.0090 | ||
distribution: uniform | ||
create copy: False | ||
Perovskite: | ||
- name: null | ||
reference product: null | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.0000 | ||
2050: | ||
min: 0.0000 | ||
max: 0.3000 | ||
distribution: uniform | ||
create copy: False | ||
GaAs: | ||
- name: null | ||
reference product: null | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.0000 | ||
2050: | ||
min: 0.0000 | ||
max: 0.1500 | ||
distribution: uniform | ||
create copy: False | ||
CSP: | ||
Parabolic trough: | ||
- name: electricity production, solar thermal parabolic trough, 50 MW | ||
reference product: electricity, high voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.9474 | ||
2050: | ||
min: 0.5 | ||
max: 0.95 | ||
distribution: uniform | ||
create copy: False | ||
Solar tower: | ||
- name: electricity production, solar tower power plant, 20 MW | ||
reference product: electricity, high voltage | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.0526 | ||
2050: | ||
min: 0.05 | ||
max: 0.5 | ||
distribution: uniform | ||
create copy: False | ||
Fuel cell - Stationary: | ||
PEMFC: | ||
- name: electricity, residential, by conversion of hydrogen using fuel cell, PEM, allocated by exergy, distributed by pipeline, produced by Electrolysis, PEM using electricity from grid | ||
reference product: electricity, from residential heating system | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.1053 | ||
2050: | ||
min: 0.1150 | ||
max: 0.85 | ||
distribution: uniform | ||
create copy: False | ||
SOFC: | ||
- name: electricity, residential, by conversion of hydrogen using fuel cell, SOFC, allocated by exergy, distributed by pipeline, produced by Electrolysis, PEM using electricity from grid | ||
reference product: electricity, from residential heating system | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.3684 | ||
2050: | ||
min: 0.117 | ||
max: 0.40 | ||
distribution: uniform | ||
create copy: False | ||
PAFC: | ||
- name: null | ||
reference product: null | ||
unit: kilowatt hour | ||
2020: | ||
value: 0.5263 | ||
2050: | ||
min: 0.0 | ||
max: 0.4750 | ||
distribution: uniform | ||
create copy: False | ||
Electrolyzer: | ||
PEM: | ||
- name: hydrogen production, gaseous, 30 bar, from PEM electrolysis, from grid electricity | ||
reference product: hydrogen, gaseous, 30 bar | ||
unit: kilogram | ||
2020: | ||
value: 0.5 | ||
2050: | ||
min: 0.5057 | ||
max: 0.75 | ||
distribution: uniform | ||
create copy: False | ||
Alkaline: | ||
- name: hydrogen production, gaseous, 20 bar, from AEC electrolysis, from grid electricity | ||
reference product: hydrogen, gaseous, 20 bar | ||
unit: kilogram | ||
2020: | ||
value: 0.50 | ||
2050: | ||
min: 0.0 | ||
max: 0.4943 | ||
distribution: uniform | ||
create copy: False | ||
HTEL: | ||
- name: hydrogen production, gaseous, 1 bar, from SOEC electrolysis, from grid electricity | ||
reference product: hydrogen, gaseous, 1 bar | ||
unit: | ||
2020: | ||
value: 0.0 | ||
2050: | ||
min: 0.0 | ||
max: 0.25 | ||
distribution: uniform | ||
create copy: False | ||
Battery-Mobile: | ||
NMC111: | ||
- name: battery cell, NMC-111 # NMC alternatives w/ hyphen: version from E. Crenna et al. (2021) | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.25 | ||
2050: | ||
min: 0.0 | ||
max: 0.22 | ||
distribution: uniform | ||
create copy: False | ||
NMC622: | ||
- name: battery cell, NMC-622 # This is the activity currently link to the transport needs | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.45 | ||
2050: | ||
min: 0.0 | ||
max: 0.45 | ||
distribution: uniform | ||
create copy: False | ||
NMC811: | ||
- name: battery cell, NMC-811 | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.05 | ||
2050: | ||
min: 0.0 | ||
max: 0.75 | ||
distribution: uniform | ||
create copy: False | ||
NCA: | ||
- name: battery cell, NCA | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.15 | ||
2050: | ||
min: 0.0 | ||
max: 0.15 | ||
distribution: uniform | ||
create copy: False | ||
LFP: | ||
- name: battery cell, LFP | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.1 | ||
2050: | ||
min: 0.0 | ||
max: 0.1 | ||
distribution: uniform | ||
create copy: False | ||
LiS: | ||
- name: battery cell production, LiS | ||
reference product: battery cell, LiS | ||
unit: kilogram | ||
2020: | ||
value: 0.0 | ||
2050: | ||
min: 0.0 | ||
max: 0.9 | ||
distribution: uniform | ||
create copy: False | ||
LiO2: | ||
- name: battery cell production, Li-O2 | ||
reference product: battery cell, Li-O2 | ||
unit: kilogram | ||
2020: | ||
value: 0.0 | ||
2050: | ||
min: 0.0 | ||
max: 0.1 | ||
distribution: uniform | ||
create copy: False | ||
#### ON BATTERIES, WE WILL BE WORKING WITH KILOGRAMS... FORGETTING ABOUT ENERGY DENSITIES :( | ||
Battery-Stationary: ### Home storage uses NMC811 (w/o hyphen) in the current premise version | ||
NMC111: | ||
- name: market for battery cell, Li-ion, NMC111 | ||
reference product: battery cell, Li-ion, NMC111 | ||
unit: kilogram | ||
2020: | ||
value: 0.24 | ||
2050: | ||
min: 0.0 | ||
max: 0.205 | ||
distribution: uniform | ||
create copy: False | ||
NMC622: | ||
- name: battery cell, NMC-622 # This activity is the same as before - We need to create a copy of the activity | ||
reference product: battery cell | ||
unit: kilogram | ||
2020: | ||
value: 0.13 | ||
2050: | ||
min: 0.02 | ||
max: 0.30 | ||
distribution: uniform | ||
create copy: True | ||
NMC811: | ||
- name: market for battery cell, Li-ion, NMC811 # Connected to home storage system | ||
reference product: battery cell, Li-ion, NMC811 | ||
unit: kilogram | ||
2020: | ||
value: 0.03 | ||
2050: | ||
min: 0.039 | ||
max: 0.44 | ||
distribution: uniform | ||
create copy: False | ||
Lead-Acid: | ||
- name: market for battery, lead acid, rechargeable, stationary | ||
reference product: battery, lead acid, rechargeable, stationary | ||
unit: kilogram | ||
2020: | ||
value: 0.10 | ||
2050: | ||
min: 0.0 | ||
max: 0.095 | ||
distribution: uniform | ||
create copy: False | ||
LFP: | ||
- name: market for battery cell, Li-ion, LFP | ||
reference product: battery cell, Li-ion, LFP | ||
unit: kilogram | ||
2020: | ||
value: 0.40 | ||
2050: | ||
min: 0.17 | ||
max: 0.40 | ||
distribution: uniform | ||
create copy: False | ||
SIB: | ||
- name: battery cell production, SIB, with NMMT cathode and fossil-HC anode | ||
reference product: battery cell, SIB, with NMMT cathode and fossil-HC anode | ||
unit: kilogram | ||
2020: | ||
value: 0.05 | ||
2050: | ||
min: 0.05 | ||
max: 0.33 | ||
distribution: uniform | ||
create copy: False | ||
Redox-Flow: # CHECK WITH ROMAIN: Different unit + Modeling in the LCA | ||
- name: vanadium-redox flow battery system assembly, 8.3 megawatt hour | ||
reference product: vanadium-redox flow battery system | ||
unit: unit # DIFFERENT UNIT!!! | ||
2020: | ||
value: 0.05 | ||
2050: | ||
min: 0.0.05 | ||
max: 0.33 | ||
distribution: uniform | ||
create copy: False |
Oops, something went wrong.