Skip to content

Modbus protocol module for use with the Azure IoT Edge

License

Notifications You must be signed in to change notification settings

terrymandin/iot-edge-modbus

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

83 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

This project has adopted the Microsoft Open Source Code of Conduct. For more information see the Code of Conduct FAQ or contact [email protected] with any additional questions or comments

Azure IoT Edge Modbus Module GA

Using this module, developers can build Azure IoT Edge solutions with Modbus TCP/RTU(RTU is currently not available in Windows environment, please use Linux host + Linux container to play with RTU mode) connectivity. The Modbus module is an Azure IoT Edge module, capable of reading data from Modbus devices and publishing data to the Azure IoT Hub via the Edge framework. Developers can modify the module tailoring to any scenario.

There are prebuilt Modbus TCP module container images ready at here for you to quickstart the experience of Azure IoT Edge on your target device or simulated device.

Visit http://azure.com/iotdev to learn more about developing applications for Azure IoT.

Azure IoT Edge Compatibility

Current version of the module is targeted for the Azure IoT Edge GA.
If you are using v1 version of IoT Edge (previously known as Azure IoT Gateway), please use v1 version of this module, all materials can be found in v1 folder.

Find more information about Azure IoT Edge at here.

Target Device Setup

Platform Compatibility

Azure IoT Edge is designed to be used with a broad range of operating system platforms. Modbus module has been tested on the following platforms:

  • Windows 10 Enterprise (version 1709) x64
  • Windows 10 IoT Core (version 1709) x64
  • Linux x64
  • Linux arm32v7

Device Setup

Build Environment Setup

Modbus module is a .NET Core 2.1 application, which is developed and built based on the guidelines in Azure IoT Edge document. Please follow this link to setup the build environment.

Basic requirement:

  • Docker CE
  • .NET Core 2.1 SDK

HowTo Build

In this section, the Modbus module we be built as an IoT Edge module.

Open the project in VS Code, and open VS Code command palette, type and run the command Edge: Build IoT Edge solution. Select the deployment.template.json file for your solution from the command palette.
Note: Be sure to check configuration section to properly set each fields before deploying the module.

In Azure IoT Hub Devices explorer, right-click an IoT Edge device ID, then select Create deployment for IoT Edge device. Open the config folder of your solution, then select the deployment.json file. Click Select Edge Deployment Manifest. Then you can see the deployment is successfully created with a deployment ID in VS Code integrated terminal. You can check your container status in the VS Code Docker explorer or by run the docker ps command in the terminal.

Configuration

Before running the module, proper configuration is required. Here is a sample configuration for your reference.

{
  "PublishInterval": "2000",
  "Version":"2",
  "SlaveConfigs": {
    "Slave01": {
      "SlaveConnection": "192.168.0.1",
      "HwId": "PowerMeter-0a:01:01:01:01:01",
      "RetryCount": "10",
      "RetryInterval": "50",
      "Operations": {
        "Op01": {
          "PollingInterval": "1000",
          "UnitId": "1",
          "StartAddress": "400001",
          "Count": "2",
          "DisplayName": "Voltage",
          "CorrelationId": "MessageType1"
        },
        "Op02": {
          "PollingInterval": "1000",
          "UnitId": "1",
          "StartAddress": "400002",
          "Count": "2",
          "DisplayName": "Current",
          "CorrelationId": "MessageType1"
        }
      }
    },
    "Slave02": {
      "SlaveConnection": "ttyS0",
      "HwId": "PowerMeter-0a:01:01:01:01:02",
      "BaudRate": "9600",
      "DataBits": "8",
      "StopBits": "1",
      "Parity": "ODD",
      "FlowControl": "NONE",
      "Operations": {
        "Op01": {
          "PollingInterval": "2000",
          "UnitId": "1",
          "StartAddress": "40001",
          "Count": "1",
          "DisplayName": "Power"
        },
        "Op02": {
          "PollingInterval": "2000",
          "UnitId": "1",
          "StartAddress": "40003",
          "Count": "1",
          "DisplayName": "Status"
        }
      }
    }
  }
}

Meaning of each field:

  • "PublishInterval" - Interval between each push to IoT Hub in millisecond
  • "Version" - Switch between the PP (Public Preview) and the latest Message Payload format. (valid value for PP: "1", all other values will switch to the latest format)
  • "SlaveConfigs" - Contains one or more Modbus slaves' configuration. In this sample, we have "Slave01" and "Slave02" two devices:
    • "Slave01", "Slave02" - User defined names for each Modbus slave, cannot have duplicates under "SlaveConfigs".
    • "SlaveConnection" - Ipv4 address or the serial port name of the Modbus slave.
    • "RetryCount" - Max retry attempt for reading data, default to 10
    • "RetryInterval" - Retry interval between each retry attempt, default to 50 milliseconds
    • "HwId" - Unique Id for each Modbus slave (user defined)
    • "BaudRate" - Serial port communication parameter. (valid values: ...9600, 14400,19200...)
    • "DataBits" - Serial port communication parameter. (valid values: 7, 8)
    • "StopBits" - Serial port communication parameter. (valid values: 1, 1.5, 2)
    • "Parity" - Serial port communication parameter. (valid values: ODD, EVEN, NONE)
    • "FlowControl" - Serial port communication parameter. (valid values: ONLY support NONE now)
    • "Operations" - Contains one or more Modbus read requests. In this sample, we have "Op01" and "Op02" two read requests in both Slave01 and Slave02:
      • "Op01", "Op02" - User defined names for each read request, cannot have duplicates under the same "Operations" section.
      • "PollingInterval": Interval between each read request in millisecond
      • "UnitId" - The unit id to be read
      • "StartAddress" - The starting address of Modbus read request, currently supports both 5-digit and 6-digit format
      • "Count" - Number of registers/bits to be read
      • "DisplayName" - Alternative name for the "StartAddress" register(s)(user defined)
      • "CorrelationId" - The Operations with same id with be grouped together in their output message

For more about Modbus, please refer to the Wiki link.

Module Endpoints and Routing

There are two endpoints defined in Modbus TCP module:

  • "modbusOutput": This is a output endpoint for telemetries. All read operations defined in configuration will be composed as telemetry messages output to this endpoint.
  • "input1": This is an input endpoint for write commands.

Input/Output message format and Routing rules are introduced below.

Read from Modbus

Telemetry Message

Message Properties:

"content-type": "application/edge-modbus-json"

Latest Message Payload:

[
    {
      "PublishTimestamp": "2018-04-17 12:28:53",
      "Content": [
        {
          "HwId": "PowerMeter-0a:01:01:01:01:02",
          "Data": [
            {
              "CorrelationId": "MessageType1",
              "SourceTimestamp": "2018-04-17 12:28:48",
              "Values": [
                {
                  "DisplayName": "Op02",
                  "Address": "40003",
                  "Value": "2785"
                },
                {
                  "DisplayName": "Op02",
                  "Address": "40004",
                  "Value": "18529"
                },
                {
                  "DisplayName": "Op01",
                  "Address": "40001",
                  "Value": "1840"
                },
                {
                  "DisplayName": "Op01",
                  "Address": "40002",
                  "Value": "31497"
                }
              ]
            },
            {
              "CorrelationId": "MessageType1",
              "SourceTimestamp": "2018-04-17 12:28:50",
              "Values": [
                {
                  "DisplayName": "Op02",
                  "Address": "40003",
                  "Value": "21578"
                },
                {
                  "DisplayName": "Op02",
                  "Address": "40004",
                  "Value": "26979"
                },
                {
                  "DisplayName": "Op01",
                  "Address": "40001",
                  "Value": "13210"
                },
                {
                  "DisplayName": "Op01",
                  "Address": "40002",
                  "Value": "13549"
                }
              ]
            }
          ]
        }
      ]
    }
  ]

PP (Public Preview) Message Payload:

[
	{
		"DisplayName":"RotaryOne",
		"HwId":"Wise4012E",
		"Address":"40001",
		"Value":"0",
		"SourceTimestamp":"2018-09-18 04:14:32"
	},
	{
		"DisplayName":"SwitchOne",
		"HwId":"Wise4012E",
		"Address":"00001",
		"Value":"1",
		"SourceTimestamp":"2018-09-18 04:14:33"
	},
	{
		"DisplayName":"RelayOne",
		"HwId":"Wise4012E",
		"Address":"00017",
		"Value":"0",
		"SourceTimestamp":"2018-09-18 04:14:33"
	}
]

Route to IoT Hub

{
  "routes": {
    "modbusToIoTHub":"FROM /messages/modules/modbus/outputs/modbusOutput INTO $upstream"
  }
}

Route to other (filter) modules

{
  "routes": {
    "modbusToFilter":"FROM /messages/modules/modbus/outputs/modbusOutput INTO BrokeredEndpoint(\"/modules/filtermodule/inputs/input1\")"
  }
}

Write to Modbus

Modbus module use input endpoint "input1" to receive commands. Currently it supports writing back to a single register/cell in a Modbus slave.
Note: Currently IoT Edge only supports send messages into one module from another module, direct C2D messages doesn't work.

Command Message

The content of command must be the following message format.

Message Properties:

"command-type": "ModbusWrite"

Message Payload:

{
  "HwId":"PowerMeter-0a:01:01:01:01:01",
  "UId":"1",
  "Address":"40001",
  "Value":"15"
}

Route from other (filter) modules

The command should have a property "command-type" with value "ModbusWrite". Also, routing must be enabled by specifying rule like below.

{
  "routes": {
    "filterToModbus":"FROM /messages/modules/filtermodule/outputs/output1 INTO BrokeredEndpoint(\"/modules/modbus/inputs/input1\")"
  }
}

HowTo Run

Run as an IoT Edge module

Please follow the link to deploy the module as an IoT Edge module.

Configure Modbus RTU

This is for Modbus RTU only, Modbus TCP could skip this section.

In the Container Create Option section, enter the following for device mapping.

{
  "HostConfig": {
    "Devices": [
      {
        "PathOnHost": "<device name on host machine>",
        "PathInContainer": "<device name in container>",
        "CgroupPermissions": "rwm"
      }
    ]
  }
}

About

Modbus protocol module for use with the Azure IoT Edge

Resources

License

Stars

Watchers

Forks

Packages

No packages published

Languages

  • C++ 41.7%
  • C# 30.4%
  • C 26.0%
  • CMake 1.9%