89 changes: 89 additions & 0 deletions source/_integrations/devolo_home_network.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -132,6 +132,95 @@ This integration only supports using the API the devolo Home Network App uses. T

The devolo Gigabridge is the only device that comes with a default password. However, it seems that in factory default the password works for the device website but not for the API. If you give the device a new password via the website, it is applied to both and the integration starts working. Even using the same password again works.

## Example automations

### Restart PLC device on loss of pairing

PLC networks are sometime flaky. In order to restore a network's state it's sometimes a good idea to reboot the PLC device attached to the router, if the number of PLC devices is lower as expected. If you apply this automation, keep in mind, that devices might be expectedly on standby. In this example, the expected number of devices is 3 and the device connected to the router is called Alexandra.

{% raw %}

```yaml
alias: PLC Feeder Restart
description: "Restart device connected to the router if number of PLC devices is unexpected low"
triggers:
- trigger: numeric_state
entity_id:
- sensor.alexandra_connected_plc_devices
for:
hours: 0
minutes: 10
seconds: 0
below: 3
conditions: []
actions:
- device_id: c38fe153e4a5b560995fd0a0850a5443
domain: button
entity_id: 5ccbb089c6208425aec3cb331dd0b716
type: press
mode: single
```

{% endraw %}

### Notify on data rate drop

Noise on the electric wire can significant disturb PLC data rates. A notification close to a drop can help identify the action that lead to the drop. The following example takes 25% as threshold.

{% raw %}

```yaml
alias: PLC Data rate
description: PLC Data rate dropped more than 25%
triggers:
- entity_id:
- sensor.nell_plc_downlink_phy_rate_alexandra
- sensor.nell_plc_uplink_phy_rate_alexandra
trigger: state
conditions:
- condition: template
value_template: >-
{{ not(0.75 < (trigger.to_state.state|float /
trigger.from_state.state|float)) }}
actions:
- action: notify.mobile_app_pixel_4a
metadata: {}
data:
message: >-
PLC data rate of {{ trigger.to_state.name }} dropped to {{
trigger.to_state.state }}
{{trigger.to_state.attributes.unit_of_measurement}}
title: PLC data rate dropped
mode: single
```

{% endraw %}

### Enable guest wifi on time basis

You might want to expose your guest wifi only during the day but turn it of at night.

{% raw %}

```yaml
alias: Toggle Guest Wifi
description: Turn Guest Wifi on and off
triggers:
- trigger: time
at: "08:00:00"
- trigger: time
at: "17:00:00"
conditions: []
actions:
- type: toggle
device_id: ec24234d5d2daf35ff57d6162d2801ab
entity_id: 4c5ef9690593dc3c77079e4045558ac8
domain: switch
mode: single
```